Radiation therapy test phantom Blue Phantom²
general purpose

Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 2
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 3
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 4
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 5
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 6
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 7
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 8
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 9
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 10
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 11
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 12
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 13
Radiation therapy test phantom - Blue Phantom² - IBA Group - general purpose - image - 14
Add to favorites
Compare this product
 

Characteristics

Type of calibration
for radiation therapy
Area of the body
general purpose

Description

3D Water Phantom System for complete LINAC Commissioning & QA The Blue Phantom² embodies decades of expertise, research and experience, providing you the best of water phantoms. *Precision: Unique absolute measurement technology *Long-term accuracy: High-precision, non-contact position sensor technology w/o non-mechanical wear *Positioning: Detector positioning certified to ± 0.1 mm accuracy Description Fastest, most Accurate and most Reliable Linac commissioning and regular QA Quality beam scanning is the cornerstone for treatment planning and delivery accuracy. The Blue Phantom², with its scanning software myQA Accept, is the leading water phantom solution for radiation therapy (RT) beam scanning. The system’s unique design facilitates faster and more accurate commissioning of RT treatment systems which is fundamental for safer patient treatments. The latest Blue Phantom2 is based on over 40 years of experience during which IBA Dosimetry has been providing high quality dosimetry equipment and services to more than 4,000 satisfied water phantom users worldwide. Technical specs Exterior water tank dimensions: 675 x 645 x 560 mm Scanning volume: 480 x 480 x 410 mm Position resolution: 0.1 mm Position accuracy: ± 0.1 mm Scanning speed: 50 mm/s Wall thickness / material: 15 mm / acrylic

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Stand S1.F10

  • More information

    Other IBA Group products

    Dosimetry

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.