– 3/2 NC Manifold mounting
– Compact design
– Long life - in excess of 100 millions cycle rate
– Low power consumption
– Certification: ATEX, IECEx
This valve was specifically designed to meet the stringent requirements of the ATEX industry, ensuring optimal performance and safety in explosive atmospheres.
Medium:
Air, oxygen, neutral gases (10 % to 95 % humidity, non condensing), 40 μm filtered
Operation:
Direct acting 3-way valves, normally closed
Flow:
12 l/min at 7 bar (101 psi) at +20 °C (+68°F)
kv factor:
0,12 (Cv: 0.008)
Mounting:
Manifold
Orifice:
0,5 mm
Response time:
25 ms
Response time measured
according to ISO 12238
Life expectancy:
20 … 100 million cycles
(except Hit & Hold valves)
Weight:
30 g (0.07 lbs)
Ambient/media temperature:
-10 ... +50 °C (+14 ... +122°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2 °C (+35°F).
Materials:
Body: PPS
Seat seals: NBR, FPM
Internal parts: Stainless steel,
PA 6/6