– 2/2 NC - Cartridge mounting
– High controllability in dosing gases in ml range
– High stability in closed loop control systems
– Cleaned for analytical applications
– Repeatable proportional characteristic
Medium:
Compressed air, neutral gases
Filtration:
Orifice sizes 0,05 … 0,3 mm:
5 μm filter already integrated
Orifice sizes 0,5 mm:
5 μm filters can be integrated on request or to be placed before the valve
Operation:
Direct acting 2-way valve
Normally closed
Operating pressure:
0 … 10 bar (0 … 145 psi)
Mounting:
Cartridge
Size:
16 mm
Orifice:
0,05 … 1,2 mm
Life expectancy:
≥ 100 Mio. cycles
Internal & external leakage:
10-3 mbar x l/s
Protection class:
IPX1
Weight:
40 g (0,09 lbs)
Ambient/media temperature:
0 … +50°C (32 … 122°F)
Air supply must be dry enough to avoid ice formation at temperatures below +2°C (35°F).
Materials:
Body: Stainless steel
Internal parts in contact with media: Stainless steel
Seals in contact with media: FPM, FFPM
Manifolds:
Contact your local fluid control specialist for information about our manifolding capabilities which include laminated polymer manifolds.