Portable patient monitor DTSF-12A
tabletopimplantable12-lead ECG

portable patient monitor
portable patient monitor
portable patient monitor
portable patient monitor
Add to favorites
Compare this product
 

Characteristics

Configuration
portable, tabletop, implantable
Measured parameter
12-lead ECG, RESP, TEMP, heart rate, IBP, ABPM, EEG, EMG, SpO2
Applications
veterinary, intensive care, for MRI, clinical, emergency, ambulatory, transport, anesthesia, for cardiology, physiology, neurology, home care
Patient condition
for high blood pressure, COPD
Technology
pulse wave analysis, electrical impedance tomography, Doppler, PTT, ABI, TBI, finger pressure
Options and accessories
with touchscreen, wireless, with built-in printer, with patient data management system, with diagnosis software
Other characteristics
continuous, plug-in module, MRI-compatible
Screen size

12.1 cm
(4.8 in)

Pulse rate

Max.: 300 unit

Min.: 15 unit

Description

DTSF-12A Patient Monitor Specification Function: ECG、RESP、TEMP、NIBP、SPO2、PR Optional: Dual IBP、CO2、 CSM、GAS、Recorder  12.1' TFT display  Optional touch screen  Digital SpO2 with excellent performance  Unique human voice alarm  720 hours trend data and 12 hours of all waveforms  Wire and wireless network  16 languages include: English, French,  German, Spanish, Portuguese, Russian and etc ECG Lead mode 5 Leads, I, II, III, AVR, AVL, AVF, V Gain 0.25, 0.5, 1, 2 Heart rate Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm accuracy ±1% resolution 1 bpm Sensitivity > 200 μV P-P Differential Input Impedance > 5 M ohm CMRR Diagnostic Mode >90 dB Monitor Mode >110 dB Surgery Mode >110 dB Electrode offset potential ±300mV Leakage Current < 10 μA PACE pulse detect range ±2~±700mV width 0.1~2ms rise time 10~100µs PACE pulse rejection range ±2~±700mV width 0.1~2ms rise time 10~100µs Baseline Recovery < 3 s After defibrillation. Signal Range ±5 mV p-p Bandwidth Surgery 1 ~ 20 Hz Monitor 0.5 ~ 40 Hz Diagnostic 0.05 ~ 130 Hz Calibration Signa1 mV p-p, -±5% accuracy ST measurement range -2.0 ~ +2.0 mV Accuracy -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater NIBP Pulse Rate Range 40 ~ 240 bpm Measure and Alarm Range Adult Mode SYS 40 ~ 280 mmHg DIA 10 ~ 220 mmHg MEAN 20 ~ 240 mmHg Pediatric Mode SYS 40 ~ 220 mmHg DIA 10 ~ 160 mmHg MEAN 20 ~ 170 mmHg Neonatal Mode SYS 35 ~ 135 mmHg DIA 10 ~ 100 mmHg MEAN 20 ~ 110 mmHg Static pressure accuracy 3mmHg Resolution 1mmHg Accuracy Maximum Mean error 5mmHg Maximum Standard deviation 8mmHg Overpressure Protection Adult 300 mmHg Pediatric 240 mmHg Neonatal 150 mmHg