Automatic biochemistry analyzer DS-261
benchtoprandom accessclinical

Automatic biochemistry analyzer - DS-261 - Jiangsu Fuyou Medical Co.Ltd - benchtop / random access / clinical
Automatic biochemistry analyzer - DS-261 - Jiangsu Fuyou Medical Co.Ltd - benchtop / random access / clinical
Automatic biochemistry analyzer - DS-261 - Jiangsu Fuyou Medical Co.Ltd - benchtop / random access / clinical - image - 2
Automatic biochemistry analyzer - DS-261 - Jiangsu Fuyou Medical Co.Ltd - benchtop / random access / clinical - image - 3
Add to favorites
Compare this product
 

Characteristics

Operation
automatic
Configuration
benchtop
Technology
random access
Sample type
clinical, blood
Other measured parameters
with immunoturbidimetry dosing
Throughput

Min.: 50 p/h

Max.: 260 p/h

Sample volume

Min.: 0.001 ml
(0.000034 US fl oz)

Max.: 0.1 ml
(0.003381 US fl oz)

Number of sample positions

50 unit

Reagent volume

Min.: 0 ml
(0 US fl oz)

Max.: 0.5 ml
(0.02 US fl oz)

Number of reagent positions

47 unit

Weight

50 kg
(110.2 lb)

Length

85 cm
(33.5 in)

Width

72 cm
(28.3 in)

Height

54 cm
(21.3 in)

Description

260 tests/hour (without ISE) Random access wth direct reading system End point, Kinetic, Fixed time, Immunoturbidimetry, Single wavelength, Bichromatic, Multi-standard, Reagent blank, Serum blank etc Sample Volume: 1-100μl, Equipped with high-precision diluter, 0.1μl/step Reagent Volume: 1-500μl, 0.1μl/step 50 sample positions. Incuding standard, control and STAT, either serum cup or primary tube available 47 reagent positions: R1:26,R2:21 With liquid level sensor, collision sensor, automatically detect reagent residue in reagent botle One independent mixer Reaction Time: 10 mintes 90 high quality UV-transmitted plastic cuvettes, and quartz glass ouvettes awailable on request 8 channels automatic washing system, waste liquid collected by high concentration and low concentratian respectively, automatically dry cuvette, water consumption is 2-4L/H Automatic alarm for malfunction Linear, Non-linear, Multi standard, K factor Sample can be diluted and retested if result is out of range or sample is insufficient Wavelength: 330nm-850nm; standand equipped with 8 fiters,4 more filters available on request Absorbance Drift: ≤0.002 Measure range: -0.1000-3.500 Temperture Drift: ±0.1℃ Carry Over: ≤0.01% Precision: 0.0001 O.D. Auto zero setting and deduct/recerd blank value for each cuvette to ensure accurate result Emergency sample test prior Equipped with automatically test error diagnosis and correcting, automatic maintenance etc. With patented auto control and calibration management functions Bar code(sample/reagent) available on request More than 5000 items and 2 million results can be edited and stored Multiple report formats available

Catalogs

No catalogs are available for this product.

See all of Jiangsu Fuyou Medical Co.Ltd‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

EXPOMED 2025
EXPOMED 2025

24-26 Apr 2025 İstanbul (Turkey)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.