X-ray radiation shielding screen 312/DS-060/1/3
examination table-mounted0.50 mm

X-ray radiation shielding screen
X-ray radiation shielding screen
X-ray radiation shielding screen
X-ray radiation shielding screen
X-ray radiation shielding screen
X-ray radiation shielding screen
X-ray radiation shielding screen
Add to favorites
Compare this product
 

Characteristics

Ionizing radiation
X-ray
Ergonomics
examination table-mounted
Lead equivalency protection
0.50 mm

Description

Collision resilient table shield with two overlapping curtains, deep attachment bracket, double friction joint and 65 cm integrated accessory rail. Top shields included. Description 137 cm wide table shields are supplied with two integrated accessory rails: 1 off, 25 mm X 10 mm x 65 cm long integrated accessory rail (fitted) 1 off, 28.6 mm X 9.5 mm x 65 cm long integrated accessory rail (supplied) Reduces exposure to scatter radiation emanating from the table or patient’s body. Patented deep attachment bracket allowing transverse table movement. Easily mounts to either side of the table allowing pivotal arm to always face the head end. Lightweight, durable structure supporting a two piece flexible lead curtain (0.5 mm lead equivalent). Fitted with a patented device enabling upward movement of the pivotal arm when in collision with C-arm equipment. Main shield, 137 cm wide x 75 cm high curtain providing a safe zone of occupancy. 72 cm wide attachment bracket slides onto a 25 mm or 28.6 mm high tableside rail (max. 11 mm depth). Securing handle position allows the shield to overhang the rail end or be repositioned further along the table. 65 cm long accessory rail – one 25 mm x 10 mm supplied and fitted, one 28.6 mm x 9.5 mm supplied. Pivotal arm with double friction pivot can swivel outwards to form a 48 cm or 65 cm wing. Self-adjusting friction pivot ensures no unwanted curtain movement even when the table is tilted. Curtains 0.5 mm lead equivalent layer is bonded to its outer covering meaning the protective layer cannot tear or fall away unnoticed. Curtain forms around an under table x-ray tube without impeding movement. .

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall H2 - Stand D14

  • More information

    Other Kenex Electro-Medical products

    Lower body protection

    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.