Characteristics

Applications
medical, dental, veterinary, podiatry, aesthetic medicine
Configuration
benchtop, compact
Function
automatic, programmable, with vacuum cycle
Sterilization chamber material
stainless steel
Options
with steam generator
Capacity

8 l
(2.11 gal)

Temperature range

Max.: 134 °C
(273.2 °F)

Min.: 121 °C
(249.8 °F)

Width

59 cm
(23 in)

Height

43 cm
(16.9 in)

Depth

36 cm
(14 in)

Description

Fisaude cares about the maintenance and durability of your autoclave. That is why we combine the quality of this autoclave with a free water distiller. Remember that if you do not use bidistilled water your autoclave will give you problems. Fisaude wants to avoid it. The Kinefis Experience 8-liter class B autoclave is fully automatic, has an extremely simple operating mechanism and is capable of performing up to five complete sterilization cycles. This 8 liter version complies with EC Directive 1023, ISO 13485 relative to small steam sterilizers. With its reliability, speed and more compact design, it is an unbeatable alternative to class B autoclaves that perform sterilization functions. The 8-liter Kinefis Experience has an LED screen that provides detailed information on all the processes that are being carried out . Thus, we will be able to see in great detail which programs will be automatically displayed on the digital screen during sterilization. If the unit overheats and exceeds the recommended pressure, the autoclave will automatically stop working to ensure operator safety. In addition, inside the autoclave, there is a separate sewage tank to collect dirty water and ensure that clean internal pipes are not contaminated; and an internal printer that gives it a functional and avant-garde look. The device is designed to be used for sanitary purposes . Security advice: - Every 150 cycles, the hermetic filter must be replaced. - Solid / unwrapped programs can only sterilize solid instruments without wrapping them, such as pliers, forceps, etc. - Failure to adjust the atmospheric pressure can stop the operation of the sterilizer.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.