Connector-ready cooling units, which is ready for immediate use. Mounted directly on top of the morgue. The units have a sturdy housing with low-noise emittance, are fully thermal, and equipped with an air-cooled compressor. The safety utilities are in accordance with EN (DIN) standards, VDE regulations and VBG guidelines. Also included is a high-capacity evaporator with automatic defrosting, an electrical temperature regulation and a digital temperature indicator with connection and protective plug.
Refrigerant: R 134A
GWP: 1430
Ambient temperature +5°C up to +45°C
TECHNICAL DATA
Temperature range:+10°C to -5°C
Voltange:230 V / 1 Ph / 50 Hz
Refrigeration capacity 0°C inside, +40°C outside:753 Watt
Rated Input (when normally running):800 Watt
Rated input:4.7 Amp
Peak current:26 Amp
Max. current:7.8 Amp
Defrost:hot gas defrosting
Weight:42 kg
Filling quantity refrigerant:0.47 kg
Compressor:
Type:hermetic
Normal power:500 Watt
Condenser:
Air flow:400 m³/h
Evaporator:
Air flow:500 m³/h
Air throw:3 m (Standard)
Dimensions W/D/H:430 x 771 x 378 mm
Dimensions opening L/W:355 x 306 mm