Connector-ready cooling unit, which is ready for immediate use. Mounted directly on top of the morgue. The units have a sturdy housing with low-noise emittance, are fully thermal, and equipped with an air-cooled compressor. The safety utilities are in accordance with EN (DIN) standards, VDE regulations and VBG guidelines. Also included is a high-capacity evaporator with automatic defrosting, an electrical temperature regulation and a digital temperature indicator with connection and protective plug.
Refrigerant: R 134A
GWP: 1430
Ambient temperature +5°C up to +45°C
TECHNICAL DATA
Temperature range:+10°C to -5°C
Voltange:400 V / 3 Ph / 50 Hz
Refrigeration capacity 0°C inside, +40°C outside:4254 Watt
Rated Input (when normally running):3400 Watt
Rated input:7.9 Amp
Peak current:69 Amp
Max. current:16.2 Amp
Defrost:hot gas defrosting
Weight:151 kg
Filling quantity refrigerant:2.00 kg
Compressor:
Type:hermetic
Normal power:3700 Watt
Condenser:
Air flow:3200 m³/h
Evaporator:
Air flow:3450 m³/h
Air throw:10 m (Standard)
Dimensions W/D/H:1075 x 1046 x 542 mm
Dimensions opening W/D:1005 x 458 mm