Class II biological safety cabinet BMB-II-"Laminar-S."-1,2 SAVVY SL
for cytostaticsISO class 5floor-standing

Class II biological safety cabinet - BMB-II-"Laminar-S."-1,2 SAVVY SL - LAMSYSTEMS - for cytostatics / ISO class 5 / floor-standing
Class II biological safety cabinet - BMB-II-"Laminar-S."-1,2 SAVVY SL - LAMSYSTEMS - for cytostatics / ISO class 5 / floor-standing
Class II biological safety cabinet - BMB-II-"Laminar-S."-1,2 SAVVY SL - LAMSYSTEMS - for cytostatics / ISO class 5 / floor-standing - image - 2
Add to favorites
Compare this product
 

Characteristics

Class
class II
Applications
for cytostatics
ISO class
ISO class 5
Configuration
floor-standing
Certifications
EN 12469, NSF/ANSI 49
Other characteristics
with HEPA filter
Sound level

58 dB

External width

1,200 mm
(47.24 in)

External depth

770 mm
(30.31 in)

External height

2,095 mm
(82.48 in)

Internal width

1,105 mm
(43.5 in)

Internal depth

610 mm
(24.02 in)

Internal height

660 mm
(25.98 in)

Weight

270 kg
(595.25 lb)

Description

The cabinet Cytos provides product, operator and environment protection for work with agents of biosafety levels 1, 2 and 3. Application of the Microbiological Safety Cabinet Personnel protection from exposure to antineoplastic (cytostatic and cytotoxic) compounds when working with such; Aseptic preparation of the antineoplastic (cytostatic and cytotoxic) products Physical isolation (containment and controlled removal from the work zone) of pathogenic biological agents (PBA) and microorganisms to prevent airborne infection of the staff and contamination of the air in the work room and to protect the environment. minimization of risk of contamination and cross-contamination of the product; the cabinet is used to equip individual work places in medical, pharmaceutical and other institutions working with pathogenic biological agents and microorganisms; the necessity of the cabinet connection to the exhaust system is determined individually by the exploitation organization judging on the analysis and assessment of the risks. In case of the cabinet connection, it must be provided the exhaust ventilation system capacity of 750-1000 m3/h. If the cabinet is used for work with pathogenic biological agents (PBA) and high-risk (especially hazardous) microorganisms, a corresponding protective (antiplague) coverall shall be used. Key Benefits Extra measures for operator and environment protection are provided in Cytos cabinet. Four intermediate cylindrical HEPA filters H14 are installed parallel to each other and located under the work chamber worktop.