Class II biological safety cabinet BMB-II-"Laminar-S."-1,5 SAVVY SL
for researchfor clean roomscontainment

Class II biological safety cabinet - BMB-II-"Laminar-S."-1,5 SAVVY SL - LAMSYSTEMS - for research / for clean rooms / containment
Class II biological safety cabinet - BMB-II-"Laminar-S."-1,5 SAVVY SL - LAMSYSTEMS - for research / for clean rooms / containment
Class II biological safety cabinet - BMB-II-"Laminar-S."-1,5 SAVVY SL - LAMSYSTEMS - for research / for clean rooms / containment - image - 2
Add to favorites
Compare this product
 

Characteristics

Class
class II
Applications
for research, for clean rooms, containment
ISO class
ISO class 5
Configuration
floor-standing
Certifications
EN 12469, NSF/ANSI 49
Other characteristics
with HEPA filter, vertical laminar flow, with sloped sliding window, motorized
Sound level

57 dB

External width

1,405 mm
(55.31 in)

External depth

610 mm
(24.02 in)

External height

700 mm
(27.56 in)

Internal width

1,405 mm
(55.31 in)

Internal depth

610 mm
(24.02 in)

Internal height

700 mm
(27.56 in)

Weight

277 kg
(610.68 lb)

Description

The biological safety cabinet Class II SAVVY SL is designed for work with agents of biosafety levels I, II and III. It provides product, operator and environment protection. KEY BENEFITS POWER DRIVEN FRONT SASH. Five specified positions of the front sash: Operating position is settled in accordance with EN 12469 Completely closed position is used in Stand-by Mode Down position – for cleaning and disinfection Up position – for loading the working chamber Stop before closing FRONT SASH STOP PRIOR TO CLOSING. Automatic stop of the front sash at 40 mm height from the surface prior to complete closing of the front opening prevents any injury of the operator’s hands. STOP AHEAD OF OBSTACLE. To ensure maximum safety, the moving front sash automatically stops in case of contact with an object or a hand of the operator. MICROPROCESSOR CONTROL SYSTEM. The cabinet is featured with a microprocessor control system that immediately informs an operator on the reduction of the level of the cabinet protection via alarm messages displayed on the touchscreen and via an audible and visible alert. The fan motor control system SintelL-1 minimizes the power consumption of the operating cabinet as well as reduces the level of acoustic and electromagnetic noise. The system of static airflow stabilization AIS LS automatically maintains the air balance in the work chamber increasing the fan rpm as filters get clogged. Upon reaching the clogging threshold, the alarm is activated. Mode monitoring system featured with audible and visible alarm indicates any disturbance of the air balance in the work chamber.

Catalogs

No catalogs are available for this product.

See all of LAMSYSTEMS‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.