On-platform ultrasound system Mirror5 Touch
for multipurpose ultrasound imagingB/Wcolor doppler

On-platform ultrasound system - Mirror5 Touch - Landwind Medical - for multipurpose ultrasound imaging / B/W / color doppler
On-platform ultrasound system - Mirror5 Touch - Landwind Medical - for multipurpose ultrasound imaging / B/W / color doppler
On-platform ultrasound system - Mirror5 Touch - Landwind Medical - for multipurpose ultrasound imaging / B/W / color doppler - image - 2
On-platform ultrasound system - Mirror5 Touch - Landwind Medical - for multipurpose ultrasound imaging / B/W / color doppler - image - 3
Add to favorites
Compare this product
 

Characteristics

Ergonomics
on-platform
Application
for multipurpose ultrasound imaging
Imaging modes
B/W, color doppler
Options
touchscreen

Description

Mirror5 Touch is designed with multiple applications to satisfy different users with varies needs on patient care. Confident in action, guaranteed by Landwind R&D team for performance with versatility, flexibility, and ease of use that provide daily value, Patent Signal Oversampling Landwind Medical won patent on Signal Oversampling. This technology can effectively avoid the two-dimensional image distortion brought by linear interpolation of the Digital Signal Controller,remove the noise outside of the blood flow, improve the sensitivity of theblood flow detected, and Increase the grayscale image resolution LW Digital Fine Foucsing The interval of traditional dynamic focusing is more than 0.154mm while digital fine focusing interval is less than 0.02mm. Each sample point can be precisely focused. Effectively improve the superficial image resolution LanSRI: Speckle Reduction Imaging By LanSRI we mean decompose the image to a group of smaller ones in pyramid structure, analysis the texture information to remove speckle noise in different scales and then reconstruct the image after the noise suppression. LanSRI can help to enhancesmooth along preferred edge direction, reduces variation within speckle region, and maintain local mean gray scale level. LanSRI can be turned on/off and 4 levels adjustable on: ϙ live images ϙ frozen images ϙ images recalled from the archive Color Flow Peak Velocity Capture Capture the peak flow signals within a certain time duration, in order to improve the low speed blood flow and low perfusion organ such as tumor blood supply. Auto IMT Automated measurement of the intima-media thickness of the carotid artery wall,

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Stand OS.A20

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.