Resuscitation ventilator PR4-G Touch
transportemergencyelectronic

Resuscitation ventilator - PR4-G Touch - Leistung Brasil - transport / emergency / electronic
Resuscitation ventilator - PR4-G Touch - Leistung Brasil - transport / emergency / electronic
Resuscitation ventilator - PR4-G Touch - Leistung Brasil - transport / emergency / electronic - image - 2
Add to favorites
Compare this product
 

Characteristics

Applications
resuscitation, transport, emergency
Type
electronic, electro-pneumatic
Patient type
infant, pediatric, adult
Ventilation mode
non-invasive, multi-mode
Configuration
portable
Other characteristics
with touch screen, with adjustable PEEP

Description

Electronic Medical Portable Ventilator Leistung PR4-g was developed to be used in medical transport inside and outside hospital, air medic rescue and emergency rooms. Electronic Medical Portable Ventilator Leistung PR4-g was developed to be used in medical transport inside and outside hospital, air medic rescue and emergency rooms. Ventilation modes ADULT / PEDIATRIC Assist-controlled VCV Assist-controlled PCV PSV / CPAP SIMV (VCV) + PSV SIMV (PCV) + PSV MMV + PSV PSV + Assured tidal volume BIPHASIC PRESSURE (APRV) NIV NEONATAL Assist-controlled VCV Assist-controlled PCV PSV / CPAP SIMV (PCV) + PSV Continuous flow assisted/controlled Nasal CPAP *Bachup ventilation available in all ventilatory modes Programmable Alarms Maximum pressure Minimum pressure Maximum tidal volume Minimum tidal volume Apnea alarm time Maximum frequency Non-programmable alarms I:E ratio inversion PEEP O2 supply fail Interrupted cycle Controls / Programmable parameters FIO2: 50-100% Rise time: 6 levels Inhalation time: 0.1 – 30 sec Frequency: 1 – 180 cpm Tidal volume: 5 – 2500 ml Inspiratory pressure: -10 – 120 H2O cm Support pressure: 0 – 80 H2O cm PEEP: 0 – 50 H2O cm Altitude compensation: 0 – 6000 msnm Inspiratory pause 0.10 - 2 seg Monitoring / output parameters Peak airway pressure: 0 – 120 H20 cm Mean airway pressure: 0 – 100 H2O cm Inspiratory tidal volume: 0 – 2500 ml Frequency: 250 bpm I:E: 49:1 – 1:99 Graphic monitors Pressure-time waveform Waveform hold Auto scale

Catalogs

PR4-G Touch
PR4-G Touch
13 Pages

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Stand SA.N11

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.