Microelectronic Fabrication, Medical Device Manufacturing, QC Inspection, Sterile Filling & Packaging, Pharmaceutical Processing, Semiconductor Manufacturing
Description:
Designed to create a clean zone with ISO-5 / Class 100 horizontal laminar airflow patterns, WM Series Horizontal airflow modules with HEPA (High Efficiency Particulate Air) filter, 99.99% efficient on .3 microns, are joined together in any width combination to form one wall, then connected to a prefabricated tubular steel frame. Tunnels are determined in size by the width and height of the HEPA filter horizontal laminar airflow wall modules combined with length of the tunnel enclosure. Ceilings & side walls are added by using clear acrylic panels and clear vinyl curtains. Air is totally displaced within the tunnel, from wall to wall & ceiling to floor. The airflow moves continuously throughout the tunnel, exiting from the open end & carrying with it airborne particulate matter. Airflow modules are individually tested and certified to meet or exceed the specifications for Laminar Flow Clean-air Devices as per Institute of Environmental Sciences IEC-RP-CC-002-86.
Construction:
2” or 3” square (tubular – 11 gauge) welded frame – Painted or Stainless Steel with heavy-duty lockable casters; Standard Inside ceiling is 8 ft. (others are available). WM Series is located at the rear of the tunnel pushing cleanroom air from rear to the front. Woodboard construction for minimum noise & vibration. White plastic laminate finish.