Medical autoclave TOUCHCLAVE
benchtoppass-throughautomatic

Medical autoclave - TOUCHCLAVE - LTE Scientific  - benchtop / pass-through / automatic
Medical autoclave - TOUCHCLAVE - LTE Scientific  - benchtop / pass-through / automatic
Medical autoclave - TOUCHCLAVE - LTE Scientific  - benchtop / pass-through / automatic - image - 2
Medical autoclave - TOUCHCLAVE - LTE Scientific  - benchtop / pass-through / automatic - image - 3
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Configuration
benchtop, pass-through
Function
automatic, electrically heated
Sterilization chamber material
stainless steel
Capacity

435 l, 545 l, 870 l, 1,052 l, 1,274 l
(114.91 gal, 143.97 gal, 229.83 gal, 277.91 gal, 336.56 gal)

Temperature range

Min.: 105 °C
(221 °F)

Max.: 137 °C
(278.6 °F)

Width

1,270 mm, 1,920 mm
(50 in, 76 in)

Height

1,900 mm, 2,035 mm
(74.8 in, 80.1 in)

Depth

2,000 mm, 2,150 mm
(79 in, 85 in)

Description

All models can be configured for either single entry or pass-through. All Touchclave Systems autoclaves are fitted with a wide selection of features as standard, designed to ensure optimum performance. The Touchclave Systems-MP operate either using the customers central steam supply, electrically heated integral or stand alone steam generators. Sterilizers can be supplied with polished chambers, stainless steel pipework and clean steam generators, and all are customisable to suit your individual needs. KEY FEATURES Automatic Sliding Doors The automatic sliding doors have a safety edge and auto-reverse system for operator safety, therefore the door will sense any obstructions during closure causing the door to stop and reverse direction preventing anything from getting trapped between the door and frame. Pre/Post vacuum system Provides quicker and more efficient air removal at the start of the cycle, ensuring that steam will penetrate deep into the load and not be affected by trapped air pockets. Can also help speed up the cooling stage, as the vacuum can be used to help dissipate heat from the load. Water Jacket Cooling System Speeds up the cooling stage of the sterilization cycle by flushing cold water through the Jacket. Air Ballast System Fluid loads, especially sealed containers, normally need to be cooled slowly in order to prevent breakage or volume loss. Air ballast provides an over pressure in the chamber during cooling allowing the fluids to be cooled faster and with a reduced risk of breakage or volume loss.