Infant incubator on casters BABYLIFE® BLF-2001G

Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika
Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika
Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika - image - 2
Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika - image - 3
Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika - image - 4
Infant incubator on casters - BABYLIFE® BLF-2001G - MEDICOR Elektronika - image - 5
Add to favorites
Compare this product
 

Characteristics

Features
on casters
Weight

70 kg
(154.3 lb)

Width

85 cm
(33.5 in)

Height

132 cm
(52 in)

Description

Humidity servo (0-95%) 3 litres distilled and residual water reservoirs Air temperature servo control w/ override (25-39 oC) Glass-like transparent single wall hood, x-ray compatible Hood with front access door Hood with 4 noiseless, easy to open hand ports / windows Hood with 2 iris ports / windows Hood with 6 tube ports Cradle with anti-decubitus mattress, x-ray compatible Space for x-ray cassette under the cradle Mechanical one step cradle tilting, up to 12 degrees Heavy duty stand with 4 castors (2 lockable) Instrument shelf on the stand Protector and instrument holder rails on each side HEPA 13 air filter State-of-the-art microprocessor controller 5” bi-colour LCD display Water resistant, foil-covered keypad with lock Test button / Self test / Silence / Reset button Display of heating intensity, date, set and actual values 3/24/170 hours trends Visual and audible alarms and backup sensors Continuous self-test function during operation Test button / Self test / Silence / Reset button RS-232 connector 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request) The functions and operation of BLF-2001 incubators meet the requirements of IEC-601-2-19 product standard and those of the 93/42/EEC Directive. The materials used comply with the hygienic and toxicological requirements and are monitored continuously. The development, production and quality assurance of the incubators are performed in accordance with the ISO 13485 and ISO 9001 standards. Alarm and warning details: High temperature / Ventilation fault / Temperature sensor fault (air sensor 1, air sensor 2, air sensor 3, skin sensor, second skin sensor, rectal sensor)

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall H4 - Stand C50

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.