Infant warmer with ventilator BabyLife® BLR-2100A
with monitorwith scalewith storage compartment

Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment
Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment
Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment - image - 2
Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment - image - 3
Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment - image - 4
Infant warmer with ventilator - BabyLife® BLR-2100A - MEDICOR Elektronika - with monitor / with scale / with storage compartment - image - 5
Add to favorites
Compare this product
 

Characteristics

Options
with monitor, with scale, with storage compartment, with ventilator
Configuration
on casters, height-adjustable
Other characteristics
with APGAR timer, with alarm, with radiant heating
Width

120 cm
(47.2 in)

Height

Min.: 185 cm
(72.8 in)

Max.: 200 cm
(78.7 in)

Weight

90 kg
(198.4 lb)

Maximum load

10 kg
(22.05 lb)

Description

Automatic warm-up Pre-warm (33 oC) & Manual mode (0-100% in 5% increments) Surface temperature servo control (30-38 oC) Skin temp. servo control (32-38 oC increments 0.1 oC) with reusable sensor Heavy duty stand with 4 castors (2 lockable, 150 mm) Protector bumpers on each side & handle on front Foldable side walls (4 pcs, height 17,5 cm) / name plate Tube ports & measure line on side walls Lying surface w/ antidecubitus mattress, x-ray compatible Cradle tilting (continuous, up to 10 degrees, both direction) Drawable x-ray cassette tray (35 x 65 cm) Turnable head by 30 and 90 degrees both direction Ceramic heaters with parabolic reflectors and protecting grid Cupboard with two drawers (300x300x90 mm) Gas cylinder holders (two) on the stand Monitor shelves (two) & IV pole on the column Dimmable halogen & LED procedure light 5” LCD display with APGAR timer Set / Display of date / time / temperature / trend, etc. Water resistant, foil-covered keypad with lock State-of-the-art microprocessor controller Visual and audible alarms and backup sensors Continuous self-test function during operation Test button / Self test / Silence / Reset button RS-232 connector 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request) Technical data LYING SURFACE (BED) SPECIFICATION Surface size 61 x 76 cm (24 x 29,9 in) Mattress size 60 x 75 x 2 cm (23,6 x 29,5 x 0,8 in) Mattress to head height 80 cm (31,5 in) TEMPERATURE CONTROL MODES Pre-warm mode 33.0°C (91.4°F) Manual control temperature mode 0%-100%, in 5% increments Surface control temperature range 30.0°C (86°F) to 38.0°C (100.4°F), in 0.1°C increments Skin control temperature range 32.0°C (89.6°F) to 38.0°C (100.4°F), in 0.1°C increments