1. Medical Technical Facilities
  2. Intensive care
  3. Home care CPAP machine
  4. Medisan Tıp Sağlık Arge Üretim Ve Ticaret A.Ş
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

BIPAP CPAP machine
home caresleep apnea therapyadult

BIPAP CPAP machine - Medisan Tıp Sağlık Arge Üretim Ve Ticaret A.Ş - home care / sleep apnea therapy / adult
BIPAP CPAP machine - Medisan Tıp Sağlık Arge Üretim Ve Ticaret A.Ş - home care / sleep apnea therapy / adult
BIPAP CPAP machine - Medisan Tıp Sağlık Arge Üretim Ve Ticaret A.Ş - home care / sleep apnea therapy / adult - image - 2
Add to favorites
Compare this product
 

Characteristics

Application domain
home care
Applications
sleep apnea therapy
Ventilation mode
BIPAP
Patient type
adult

Description

Bilevel Positive Airway Pressure is a non-invasive treatment method for patients with sleep apnea with a mask that supplies compressed breathing air through a mask to prevent potential collapses or blockages in the lungs and breathing tubes. Allows the patient to breathe himself. GOLDSLEEP Bipap S device also has a BACKUP FREQUENCY system to protect the patient. Thanks to this system, if the patient does not breathe for any reason, the device monitors the patient for 10 seconds and starts breathing at the end of this period. Technical Specifications: IPAP 3 - 30 mbar (up to 30.0 mbar in 0.1 mbar increments) Breathing. EPAP 3 - 30 mbar (up to 30.0 mbar in 0.1 mbar increments) Exhaling. RAMP TIME OFF / 5-10-15…90 MIN RAMP PRESSURE It can be adjusted between 3 - 30 mbar. It gradually rises to the IPAP / EPAP value. I-SLOPE OFF / 1-2-3-4-5 Length/rate of patient's breathing time (Time taken by the device to go from EPAP (positive exhalation pressure level) to IPAP (positive exhalation pressure level). E-SLOPE OFF / 1-2-3-4-5 Length/rate of patient's exhalation time (Time taken by the device to descend from IPAP (positive inspiratory pressure level) to EPAP (positive exhalation pressure level). I SENSITIVITY OFF / 1-2-3-4-5 It is the sensitivity to detect inspiration (the sensitivity to detect the beginning of the breathing phase of breathing.). E SENSITIVITY OFF / 1-2-3-4-5 It is the sensitivity to detect expiration (the sensitivity to detect the beginning of the exhalation phase of breathing.).

VIDEO

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.