Automatic hematology analyzer BC-6800Plus
benchtop5-part differentiationlaser scattering

Automatic hematology analyzer - BC-6800Plus - Mindray - benchtop / 5-part differentiation / laser scattering
Automatic hematology analyzer - BC-6800Plus - Mindray - benchtop / 5-part differentiation / laser scattering
Automatic hematology analyzer - BC-6800Plus - Mindray - benchtop / 5-part differentiation / laser scattering - image - 2
Automatic hematology analyzer - BC-6800Plus - Mindray - benchtop / 5-part differentiation / laser scattering - image - 3
Add to favorites
Compare this product
 

Characteristics

Operation
automatic
Configuration
benchtop
Leukocyte differentiation
5-part differentiation
Technology
laser scattering
Loading capacity
100 samples
Other characteristics
computer-assisted, with sample autoloader
Throughput

200 p/h

Description

Based on the new SF Cube technology platform, the BC-6800Plus could provide more reliable blood cell results and abnormal cells flagging results with anticipated warning messages, exceeding clinicians’ expectations and setting a new standard for blood analysis. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells, which is the key to revealing more abnormal cells. NRBC result in every CBC In WNB scattergram, BC-6800Plus provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6800Plus without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. More accurate RET and PLT-O result By utilizing the new fluorescent dye, the reticulocytes and platelets are more specific stained with stronger fluorescent signal, that brings more reliable reticulocyte and platelet results.

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall S1 - Stand A10

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.