Automatic hematology analyzer BC-6000
benchtop5-part differentiation60 samples

Automatic hematology analyzer - BC-6000 - Mindray - benchtop / 5-part differentiation / 60 samples
Automatic hematology analyzer - BC-6000 - Mindray - benchtop / 5-part differentiation / 60 samples
Automatic hematology analyzer - BC-6000 - Mindray - benchtop / 5-part differentiation / 60 samples - image - 2
Automatic hematology analyzer - BC-6000 - Mindray - benchtop / 5-part differentiation / 60 samples - image - 3
Automatic hematology analyzer - BC-6000 - Mindray - benchtop / 5-part differentiation / 60 samples - image - 4
Add to favorites
Compare this product
 

Characteristics

Operation
automatic
Configuration
benchtop
Leukocyte differentiation
5-part differentiation
Loading capacity
60 samples
Other characteristics
computer-assisted, with sample autoloader
Throughput

110 p/h

Sample volume

0.035 ml, 0.08 ml
(0.00118 US fl oz, 0.00271 US fl oz)

Description

At Mindray, we seek to understand the needs of every customer, and deliver tailor-made solutions. In today’s laboratories, lab managers are looking for an analyzer with greater clinical values, such as higher flagging efficiency to reduce the ratio of microscopic examination, NRBC/body fluid results generated in a small-footprint system, among others, all within limited budget. SF Cube Technology With the newly designed opticals and reagent systems, the SF Cube technology can help doctors to better differentiate the clusters of cells NRBC result in every CBC In WNB scattergram, BC-6000 provides NRBC, Basophils and WBC-N* results. It means that the actual number of NRBCs can be measured in routine CBC, if they are present in the sample. Basophils are counted in this counting channel with NRBC results. Basophil and NRBC results are generated on BC-6000 without extra reagent or cost. NLR parameter in each CBC+DIFF Neutrophil-to-lymphocyte ratio (NLR) is calculated by dividing neutrophil count by lymphocyte count, usually from peripheral blood sample. In laboratory medicine, NLR is used as a marker of subclinical inflammation. According to clinical studies, NLR can be used as a prognostic factor of severe illness in COVID-19 patients. Automatic Rerun & Reflex Should the sample results trigger the criteria, the sample rack can automatically step back for a “rerun” or “reflex” check.

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall S1 - Stand A10

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.