Radiation therapy test phantom QUASAR™ IsoCenter Cube
general purpose

Radiation therapy test phantom - QUASAR™ IsoCenter Cube - Modus Medical Devices - general purpose
Radiation therapy test phantom - QUASAR™ IsoCenter Cube - Modus Medical Devices - general purpose
Radiation therapy test phantom - QUASAR™ IsoCenter Cube - Modus Medical Devices - general purpose - image - 2
Radiation therapy test phantom - QUASAR™ IsoCenter Cube - Modus Medical Devices - general purpose - image - 3
Add to favorites
Compare this product
 

Characteristics

Type of calibration
for radiation therapy
Area of the body
general purpose

Description

The QUASAR™ IsoCenter Cube is designed to implement a modified Winston-Lutz test for IGRT accuracy required for optimal treatment delivery. This system is also used for TG-142 quality assurance compliance for isocenter and laser alignment tests. End-to-end positioning accuracy from planning CT to clinical IGRT treatment setup is achieved with 0.1 mm precision and is accomplished in minutes. The test is performed by aligning the QUASAR™ IsoCenter Cube phantom using the cross-hairs etched on each side with your IGRT system, then capturing radiation field exposures with film or EPID. The test results are used to determine end-to-end isocenter accuracy for frameless SRS, SBRT, and IGRT treatments. Features Workflow Efficiency Quick and simple Winston-Lutz testing for IGRT accuracy. Integrate the QUASAR™ IsoCentre Cube into your daily QA routine for simple verification of your laser, isocentre and couch adjustment alignment. Simple Design The QUASAR™ IsoCenter Cube Phantom features a seamless 5 cm³ acrylic unibody enclosure containing one 6 mm diameter Tungsten Sphere located at the central axis of the main cross-hairs and used for measuring isocenter accuracy. Image Match Verification Displayed on three faces of the QUASAR™ IsoCenter Cube Phantom are 3 mm offset laser alignment marks, which are used to easily verify the couch position adjustment accuracy after image matching. Isocentre Verification User confidence is increased with the verification of your isocentre alignment accuracy. Report detailed statistics including left/right, superior/inferior and anterior/posterior errors at configurable gantry, collimator and table angles.
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.