Designed for pathological dissection, various sizes available on a bespoke basis. Links into fume extraction system.
Ventilates at working position.
Recessed to allow space for feet when standing at the table.
All outside surfaces cleaned and polished to DP1 finish
Ventilation
Containment of hazards achieved by pulling air. through peripheral edge of table.
Sump irrigation system.
Top removable to allow access to sump area for cleaning.
Standard Fittings Include:
Hot and Cold water wrist action mixer tap.
Cold water sump irrigation system.
Cold water work top irrigation system.
Quick release water outlet.
One hand trigger operated shower and hose.
2 piece dissection tray with peripheral ventilation.
Easily removable front and side panels as required.
Designed for floor fixing, recommended to be mounted on 50mm (2″) high platform to prevent water ingress.