Intraoral X-ray system RXDC
wall-mountedanalog or digital60 kV

Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 2
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 3
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 4
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 5
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 6
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 7
Intraoral X-ray system - RXDC  - MyRay - wall-mounted / analog or digital / 60 kV - image - 8
Add to favorites
Compare this product
 

Characteristics

Type of system
intraoral X-ray system
Ergonomics
wall-mounted
Technology
analog or digital
Tube voltage (kV)
60 kV, 70 kV, 65 kV
Focal spot size (mm)
0.4 mm

Description

Highest quality with lowest exposure. Always-sharp images, versatility and meticulous attention to patient health. With RXDC you get the best DC technology with the lowest X-ray dose. High frequency dc generator for sharp images and lower effective dose The constant potential high frequency generator (DC) provides sharp images with the very highest level of detail. Compared to AC systems, they also reduce exposure times and the amount of harmful radiation by containing the dose administered to the patient. Precision diagnostics Superb image definition: sharp edges and excellent detail. An embedded collimator cone gives a source-to-skin distance of 30 cm. This increases X-ray parallelism, providing more precise images, lower doses and ensuring greater attention to patient health. RXDC offers maximum flexibility and optimum X-ray quality whatever the type of sensor connected. IMMEDIATE CONFIGURATION Multi-Mode automatic exposure parameter modulation always ensures optimal time and power selection. Parameters are, in fact, adjusted automatically according to patient build and the region under investigation. MINIMUM EXPOSURE Attention to patient health is meticulous thanks to the constant potential DC generator with adjustable power (from 8 to 4 mA). Moreover, rectangular collimators can be used: these reduce the irradiated body area and thus lower the dose received by the patient.

Catalogs

RXDC
RXDC
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.