1. Surgery unit
  2. Anesthesia
  3. Trolley-mounted anesthesia workstation
  4. Nanjing Chenwei Medical Equipment Co.,Ltd

Trolley-mounted anesthesia workstation CWM-RC
with respiratory monitoringwith ventilatorwith electronic gas mixer

Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer - image - 2
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer - image - 3
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer - image - 4
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer - image - 5
Trolley-mounted anesthesia workstation - CWM-RC - Nanjing Chenwei Medical Equipment Co.,Ltd - with respiratory monitoring / with ventilator / with electronic gas mixer - image - 6
Add to favorites
Compare this product
 

Characteristics

Ergonomics
trolley-mounted
Options
with respiratory monitoring, with ventilator, with electronic gas mixer

Description

Integrated breathing circuit with APL valve, excellent tightness and easy to use. Low essential resistance, good mechanical compliance. Replacing drive bellow is not required when operating pediatric anesthesia. Drain cup design ensure no water trap in the breathing circuit. Built-in design duo flow sensor (no maintenance required). 2 L Large volume of C02 canister. Autoclave 134 °C. Technique Specifications Physical Spécifications Dimensions: 70*85* 140cm Weight: 65kg Casters: Front kstieets with lock Screen: 10.6 inch LCD Working Specifications Power - AC 220V±10%. 50Hz±2% Output pressure - 0.4i0.1MPa Current - 500mA max Pipeline Supply Gas configuration 07. NtO, Air Pipeline input range 280-600kPa Battery Power Battery type Lcad-acid 12 V. 4Ah Rim-timo Typical 30 mins*, up to 2 hrs Pre-setting Functions Language English Calibration Automatic Applications Patient range Audlt/ Pédiatrie Ventilator Specifications Modes of Ventilation vcv Volume Controlled Ventilation SIMV Synchronized Intermittent Mandatory Ventilation MANUAL Manual SIPPV (A/C) - Synchronized Intermittent Positive Pressure Ventilation PCV Pressure Control Ventilation PSV Pressure Support Ventilation STAND-BY STAND-BY PRVC Pressure-reguiated Volume Controf
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.