1. Laboratory
  2. Laboratory medicine
  3. Infectious disease test kit
  4. Nanjing Poclight Biotechnology Co., Ltd.

Infectious disease test kit
serum Amyloid Aserumplasma

Infectious disease test kit - Nanjing Poclight Biotechnology Co., Ltd. - serum Amyloid A / serum / plasma
Infectious disease test kit - Nanjing Poclight Biotechnology Co., Ltd. - serum Amyloid A / serum / plasma
Infectious disease test kit - Nanjing Poclight Biotechnology Co., Ltd. - serum Amyloid A / serum / plasma - image - 2
Infectious disease test kit - Nanjing Poclight Biotechnology Co., Ltd. - serum Amyloid A / serum / plasma - image - 3
Add to favorites
Compare this product
 

Characteristics

Applications
for infectious diseases
Tested parameter
serum Amyloid A
Sample type
serum, plasma
Analysis mode
immunoassay, chemiluminescence

Description

It is mainly used for in vitro quantitative detection of serum amyloid A (SAA) content in human serum and plasma. Intended Use Serum amyloid A is an acute-phase protein whose concentrations in the blood can increase sharply within hours during inflammatory, infectious, and non-infectious diseases. Can be increased to 1000 times the original concentration. Serum amyloid A is associated with high-density lipoprotein (HDL), which regulates HDL metabolism during inflammation. As with C-reactive protein (CRP) (similar), the detection of serum amyloid A is useful in diagnosing inflammation, assessing its activity, monitoring its activity, and treating it. Advantage No cold chain required. Single packaging. Compact and convenient. Principle Serum Amyloid A Test Kit (Chemiluminescence Immunoassay) adopts the chemiluminescence competition method. Main Components 25 Lyophilization sphere reagents Sample Requirements 1. The serum is recommended to be collected by ordinary serum collection tubes or tubes with procoagulant. If it cannot be used immediately, it is recommended to be stored at 2-8℃ and the test should be completed within 24 hours. If the test cannot be performed within 24 hours, the sample needs to be frozen at -20℃ for 1 month. 2. Samples containing sediment or flocculent material should be centrifuged (4000rpm, 10min) and then tested. 3. Samples must be returned to room temperature (15-30℃) before testing. Frozen samples should be completely thawed, rewarmed and mixed well before use. Do not repeatedly freeze and thaw. 4. Heat inactivated samples, hemolysis and other abnormal samples should be discarded.

Catalogs

No catalogs are available for this product.

See all of Nanjing Poclight Biotechnology Co., Ltd.‘s catalogs

Other Nanjing Poclight Biotechnology Co., Ltd. products

Human Analyzer

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.