1. Products
  2. Medical device fitting
  3. NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD.

Medical device fitting B-611

Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD.
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD.
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 2
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 3
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 4
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 5
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 6
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 7
Medical device fitting - B-611 - NANJING RUNZE FLUID CONTROL EQUIPMENT CO., LTD. - image - 8
Add to favorites
Compare this product
 

Characteristics

Applications
for medical devices

Description

Flangeless Fittings benefits a lot for low pressure and gastight removable systems which comes with a nut and a ferrule as a unit set to connect rigid tubing of outer diameter 1.6/2.0/2.5/3.0/3.175/3.2mm into a same thread receiving port, it is very convenient to use by hand tightened without any tools and easy to mounting into fluid systems. Application Note of Flangeless Fittings 1. Choose 1/4-28 nut when receiving port is 1/4-28; Choose M6 nut when receiving port is M6. 2. Before connecting fittings, ensure the end of the tubing has a clean, square, burr-free cut. This is very important, as the square cut helps the tubing make full contact with the bottom of the mating port. Neglecting to properly cut the tubing could lead to dead volume, resulting in peak distortion such as fronting, tailing or broadening. 3. Two-Piece Fittings Installation Steps: a. Slide the nut, followed by the ferrule, at least 3/16” (4.7625mm) from the end of the clean cut tubing b. Insert the assembly into the receiving port, pushing the tubing into the port until it bottoms out. c. Finger tighten the nut into the port until snug. d. After several uses (especially at high pressure) the ferrule should be replaced.

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.