Pad ECG electrode NeoHeart®
monitoringchestradiolucent

Pad ECG electrode - NeoHeart® - Neotech Products - monitoring / chest / radiolucent
Pad ECG electrode - NeoHeart® - Neotech Products - monitoring / chest / radiolucent
Pad ECG electrode - NeoHeart® - Neotech Products - monitoring / chest / radiolucent - image - 2
Pad ECG electrode - NeoHeart® - Neotech Products - monitoring / chest / radiolucent - image - 3
Pad ECG electrode - NeoHeart® - Neotech Products - monitoring / chest / radiolucent - image - 4
Add to favorites
Compare this product
 

Characteristics

Type
pad
Applications
monitoring
Zone of use
chest
Other characteristics
radiolucent

Description

3-in-1 pre-wired electrode array Pre-measured sensor position Radiolucent material nearly invisible on x-rays One touch application ideal for use in delivery room Larger surface area for enhanced adherence Engineered for back application, allowing chest to remain exposed Multi-colored wires for easier identification Not made with natural rubber latex or plasticizer DEHP Individually packaged Heart rate is a major indicator for decision-making during delivery room assessment of a newborn. The NeoHeart ECG Pad is the ideal answer to the latest NRP recommendations. It’s designed for short-term use during labor and delivery. The pre-measured electrode placement allows for one touch application, rather than placing three individual leads. Unlike our NeoLead electrodes, NeoHeart does not have hydrocolloid so there is no warming time. And there’s no need to wipe the baby clean first. NeoHeart has a larger surface area with a stronger adhesive for better adherence over vernix. Application Step 1 Wipe and remove any excess moisture from where NeoHeart will be applied. Step 2 Peel and discard liner. Apply immediately after liner is removed Step 3 Place NeoHeart on patient’s back and connect to ECG monitor cable. The pad should be oriented so the point of the heart is pointing toward lower extremities. Step 4 Confirm quality of ECG tracing. Note: if QRS is stable but appears small or dampened, consider changing to a different lead on the monitor or increasing the size of the waveform. If small or dampened waveform persists, application to the patient’s chest may result in a stronger waveform.

VIDEO

Catalogs

No catalogs are available for this product.

See all of Neotech Products‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall H1 - Stand C18

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.