Infant radiant warmer with phototherapy lamp HKN-93C
with oxygen cylinderwith storage compartmenton casters

Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters - image - 2
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters - image - 3
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters - image - 4
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters - image - 5
Infant radiant warmer with phototherapy lamp - HKN-93C - Ningbo David Medical Device - with oxygen cylinder / with storage compartment / on casters - image - 6
Add to favorites
Compare this product
 

Characteristics

Options
with phototherapy lamp, with oxygen cylinder, with storage compartment
Configuration
on casters, height-adjustable
Other characteristics
with alarm

Description

Build a safe neonatal surgical emergency place to effectively save the rescue time of emergency diseases Masimo pulse oximetry monitoring function 1) Measure blood oxygen and pulse effectively during motion and low perfusion; 2) The sensitivity of screening for severe congenital heart disease (CCHD) can be increased to 93%; 3) Can significantly reduce the incidence of severe retinopathy (ROP) in premature infants. User-friendly design 1) Warmer module could be rotated horizontally in both directions; 2) X-ray cassette under the bassinet; 3) The inclination of infant bassinet could be adjusted. Resuscitation Unit 1) T-piece resuscitator unit: offer a safety, stable and controllable target PIP and delivering consistent PEEP to help establish FRC and improve lung volume for the infant <10kg; 2) Suction unit (Venturi): using Venn's pneumatic negative pressure suction device professional for the cleaning of newborn respiratory tract; 3) Air-oxygen blender unit: provide and convey accurately controlled mixed air and oxygen gas to the patient in clinical use. VHA stand The height can be adjusted freely while operating, meet the operation of medical staff of different heights. Large storage drawer Enough space are convenient to store all kinds of medical accessories. Air source Provides a variety of air source connection mode, may connect the wall center supply air or install air/oxygen tanks directly.