Class II biosafety cabinet LabGard
laboratorysterilefloor-standing

Class II biosafety cabinet - LabGard - NuAire Laboratory Equipment - laboratory / sterile / floor-standing
Class II biosafety cabinet - LabGard - NuAire Laboratory Equipment - laboratory / sterile / floor-standing
Class II biosafety cabinet - LabGard - NuAire Laboratory Equipment - laboratory / sterile / floor-standing - image - 2
Class II biosafety cabinet - LabGard - NuAire Laboratory Equipment - laboratory / sterile / floor-standing - image - 3
Class II biosafety cabinet - LabGard - NuAire Laboratory Equipment - laboratory / sterile / floor-standing - image - 4
Add to favorites
Compare this product
 

Characteristics

Class
class II
Applications
laboratory, sterile
Configuration
floor-standing
Other characteristics
total exhaust

Description

The LabGard NU-L121 custom Class II Biosafety Cabinet provides personnel, product, and environmental protection for applications involving laboratory automation robotics systems. Model NU-L121 is designed as a multiple-piece unit to be assembled onsite. The cabinet can be designed as a Type A2 BSC allowing for recirculation of work zone air or a Type B2 BSC exhausting workzone air without recirculation. The NuAire custom design process ensures the customized product meets your facility space, workflow, and product needs. THE PERFECT FIT CUSTOM DIMENSIONS The LabGard NU-L121 interior work zone is designed around your laboratory solution. Custom height, width, and depth dimensions ensure the robotic lab systems fit within the sterile work zone while accounting for enough room for proper airflow and access by users when needed. FLEXIBLE DESIGN TYPE A2 OR B2 The NU-L121 can be designed as a Class II, Type A2, or Type B2 Biosafety Cabinet (BSC). Both offer personnel, product, and environmental protection, but Type A2 recirculates 70% of its air while exhausting the remaining 30%. The A2 cabinet can be recirculated back into the laboratory environment or exhausted through a facility system. The Type B2 BSC is a total exhaust cabinet meaning 100% of the air entering the cabinet is exhausted through a facility HVAC system. The Type B2 cabinet is ideal when working with volatile chemicals, which can be determined after a risk assessment.