Single-channel potentiostat EmStatMUX8-R2
USB

Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB
Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB
Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB - image - 2
Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB - image - 3
Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB - image - 4
Single-channel potentiostat - EmStatMUX8-R2 - PalmSens - USB - image - 5
Add to favorites
Compare this product
 

Characteristics

Other characteristics
USB, single-channel

Description

with integrated 8 channel multiplexer potential range: ± 3V or ± 4V compliance voltage: ± 5V or ± 8V current ranges: 1 nA – 100 mA maximum current: ± 100 mA Description With the EmStat3MUX8-R2 you can connect arrays or other setups made of up to eight working electrodes in two or three electrode cell types. If more channels are required, one or more MUX-R2 can be stacked to the EmStatMUX8-R2 for a total of up to 128 channels. The potentiostat is controlled as well as powered by USB and is used with PSTrace. The MUX8-R2 can sample different cells at a rate of 25 ms/cell. Usually a method needs to be finished to switch the cell but the fast sampling per cell makes it possible to measure time depending techniques, e.g. chronoamperometry, practically simultaneously. Via the script window of PSTrace it is also possible to perform a different experiment on each of the channels sequentially. Techniques Voltammetric techniques Linear Sweep Voltammetry (LSV) Cyclic Voltammetry (CV) Pulsed techniques Differential Pulse Voltammetry (DPV) Square Wave Voltammetry (SWV) Normal Pulse Voltammetry (NPV) Galvanostatic techniques Open Circuit Potentiometry (OCP) Amperometric techniques Chronoamperometry (CA) Zero Resistance Amperometry (ZRA) Chronocoulometry (CC) MultiStep Amperometry (MA) Pulsed Amperometric Detection (PAD) Multiple-Pulse Amperometric Detection (MPAD) Specifications dc-potential range ± 3.000 V - ± 4.000 V compliance voltage ± 5 V - ± 8 V dc-potential resolution - 0.1 mV - 0.125 mV dc-potential accuracy - 0.2 % - 0.3 % current ranges 1 nA to 10 mA (8 ranges) - 1 nA to 100 mA (9 ranges)

VIDEO

Catalogs

No catalogs are available for this product.

See all of PalmSens‘s catalogs
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.