Oxygen therapy hyperbaric chamber Sigma 40
monoplace

oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
oxygen therapy hyperbaric chamber
Add to favorites
Compare this product
 

Characteristics

Application
oxygen therapy
Number of seats
monoplace
Maximum working pressure

Max.: 6.2 bar
(89.9 psi)

Min.: 3.4 bar
(49.3 psi)

Length

2.7 m
(8'10" )

Height

1.7 m
(5'06" )

Width

1.2 m
(3'11" )

Empty weight

1,293 kg
(2,851 lb)

Description

Continuing as the leader in the industry, Perry is proud to introduce the SIGMA 40 monoplace hyperbaric chamber to its line of innovative products. This system has a 40.5” Internal Diameter chamber, the largest in the industry, which significantly reduces the incidence of noncompliance due to claustrophobia as well as allowing the treatment of the bariatric population. While the internal diameter has increased, the new technology used to build the Sigma 40 has enabled Perry to decrease the weight of the chamber by 1,650 lbs. resulting in fewer limitations due to weight restrictions. The SIGMA 40 hyperbaric chamber system features: A 40.5” internal diameter cylinder Cool and quiet treatment compartment Patient controlled temperature Adjustable stretcher and certified for patients up to 700 lbs. Extra wide stretcher with patient safety handrails Gurney adjustments of 15°, 25°, 35°,45°, 55°, and 57 ½° Optional 22” flat screen TV with CD and DVD features Intrinsically safe two-way communications system Building Service Requirements The following requirements must be met for proper operation of the SIGMA 40 Monoplace Hyperbaric System. Building must adhere to construction requirements specified in NFPA 99, Health Care Facilities. Optimal patient comfort is achieved if the room is maintained at 68°-72° F (20°-22.2° C). Flooring should not produce static electrical discharge. Carpeting is not recommended. Conductive flooring is preferred but not required.

Catalogs

Sigma 40
Sigma 40
2 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.