Intensive care ventilator AD-III
emergencyelectronicpediatric

Intensive care ventilator - AD-III - Pigeon Medical - emergency / electronic / pediatric
Intensive care ventilator - AD-III - Pigeon Medical - emergency / electronic / pediatric
Intensive care ventilator - AD-III - Pigeon Medical - emergency / electronic / pediatric - image - 2
Intensive care ventilator - AD-III - Pigeon Medical - emergency / electronic / pediatric - image - 3
Add to favorites
Compare this product
 

Characteristics

Applications
intensive care, emergency
Type
electronic
Patient type
pediatric
Ventilation mode
CPAP
Configuration
on casters

Description

AD-III NCPAP Precision automatic balancing pressure stabilizer CPAP control valve and CPAP pressure generator, output stable CPAP pressure value, precise pressure monitoring system and safety protection valve to ensure patients using safe electronic control or automatic control temperature humidifier to ensure good humidification system status. A variety of light catheters and nasal congestion reduce the patient's breathing. The fixation device of this type of NCPAP machine is convenient and fast, reducing the pressure on the patient's head and face and nasal septum injury. Our AD-III series is widely used in ICU, NICU, PICU, and emergency room. Working Principle of AD-III NCPAP The air passes through the air oxygen mixer, the pressure relief valve monitors the pressure difference warning function, adjusting the air oxygen concentration ratio into the humidifier, transports the most suitable oxygen concentration into the human respiratory channel. Features of AD-III NCPAP Double oxygen supply interface for other purposes Built-in air oxygen mixer and pressure gauge, more accurate data reading, standard factory equipped with oxygen meter. Standard general purpose compressor, provide large flow air source, reinforced load-bearing support. Specification of AD-III NCPAP FIO2 - 21-100% (±3%) CPAP - 0-10cm H2O Pressure Gauge - 0-25cm H2O Flow - 2-18 LPM Noise - ≤55dB(A) Power Source - AC 220V, 50-60Hz (Optional: AC 110V, 50-60Hz) Gas source - Air/Oxygen@0.3-0.4MPa Alarm - Gas supply pressure difference > 0.1MPa Pressure Safety Valve - 20cm H2O Humidifier - Standard: PN-2000F/ PN-2000FA

Catalogs

No catalogs are available for this product.

See all of Pigeon Medical‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Stand Z5.A51

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.