Germicidal lamp BCS series
medicalfluorescentUV

Germicidal lamp - BCS series - PME - medical / fluorescent / UV
Germicidal lamp - BCS series - PME - medical / fluorescent / UV
Germicidal lamp - BCS series - PME - medical / fluorescent / UV - image - 2
Germicidal lamp - BCS series - PME - medical / fluorescent / UV - image - 3
Germicidal lamp - BCS series - PME - medical / fluorescent / UV - image - 4
Germicidal lamp - BCS series - PME - medical / fluorescent / UV - image - 5
Germicidal lamp - BCS series - PME - medical / fluorescent / UV - image - 6
Add to favorites
Compare this product
 

Characteristics

Other characteristics
germicidal
Applications
medical
Light source
fluorescent, UV
Configuration
wall-mounted, on casters, ceiling-mounted
Power

15 W, 30 W, 55 W

Description

BACTERICIDE DEVICE BCS 2000 are intended for the air and object surface sterilization by means of UV radiation. They are recommended for use in medical ambients (surgical theaters, intensive care, infective disease, maternity hospital etc.), but also can be used in the crowded rooms (waiting halls, apothecary's shops, kindergartens etc.). Bactericide lamps are very useful in the plants for food processing and stocking. Radiation source used in BCS 2000 is a special fluorescent tube (quicksilver of low pressure) which radiates characteristic ultra-violet light,with optimal bactericide efect on 253.7 nm. Increased absorbed dose of UV radiation can cause harmful efects (conjuctivitis, erythem), so it is important to consider following recommendation of the American Medical Association: a) at steady radiation exposure, UV radiation intensity must not be greater than 0.1mW/cm2. b) at exposures equals or shorter than 7 hours/day,intensity must not be greater than 0.5mW/cm2. If personnel should work longer periods of time in the UV radiation zone, and intensity of radiation exceeds recommended one, it is necessary to use protective creams and glasses. Lamps of this type are mounted on the wall, and can be fixed or adjustable. The lamp housing is made of aluminum profiles or pickled sheet-metal. SYSTEM ELEMENTS DESCRIPTION BACTERICIDE WALL LAMP (BCS 2011) DIMENSIONS: ø 70 x 1300 mm RADIATING AREA: 50 x 900 mm COLOUR: white (RAL 9010) and E0 SUPPLY VOLTAGE: 220 V, 50 Hz LAMP POWER: 30 W BCS 2011 is mounted on the wall, the most frequently above the door, 2.1m from the floor, and can be positioned ± 900 upwards or downwards.