Characteristics

Number of channels
1-channel
Applications
veterinary, for drug delivery
Patient type
for animals
Other characteristics
portable
Infusion rate

Max.: 2 l/h
(0.528 us gal/h)

Min.: 0 l/h
(0 us gal/h)

Bolus rate (dose)

Max.: 2 l/h
(0.528 us gal/h)

Min.: 0 l/h
(0 us gal/h)

KVO/TKO flow rate

Max.: 0.0005 l/h
(0.0001 us gal/h)

Min.: 0.0001 l/h
(0 us gal/h)

Weight

1.3 kg
(2.87 lb)

Length

165 mm
(6.5 in)

Width

103 mm
(4.1 in)

Height

100 mm
(3.9 in)

Description

1) Colorful touch screen, easy to operate with human-computer interface.  2) Unique doorless design, visible place the IV set directly, convenient and quick. Dual CPU control.  3) IP34 dustproof and waterproof design. AC/DC power, Larger battery, long working time.  4) Reduce the bubbles error alarm because horizontal place the IV set design.  5) Very Light weight only 1.3 KG, small and exquisite, convenient to carry and transport.  6) DPS dynamic pressure monitoring, real-time display of the current pressure value.  7) Infusion Mode : Rate Mode/Time Mode/Weight Mode/Sequential Mode / Drip Setting. Technical specification: Power: 100~240V,    External DC Power: 12V~15V  Battery: 3000mAh, working 10 hours in 25ml/h speed.  Double CPU.    IP34warterproof / dustproof/shockproof. Flow Rate range: 0.1~2000.00ml/h, increment 0.01ml/h. VTBI:  0.1-9999.99ml,    Time: 1s-99h59min. KVO:  0.1~5.0ml/h,  increment 0.1ml/h.  Drug library: 34 units.  Accuracy: ±5%  (use the IV set calibrated).    Purge: 0.1-2000ml/h. Bolus rate: 0.1~2000ml/h, Automatic/Manual bolus available  Anti-bolus:  Automatically reduce the tube pressure when the tube is blocked. Bubble size: Adjustable 50/100/250/500/800μl.  Auto calculate the accumulation bubbles during infusion. Ultrasonic detection.  Occlusion pressure :  Adjustable Low /Medium /High.Double Pressure detection History Record:  2000 above. Night mode: setting and adjustable. Temperature:-20℃-55℃,Relative humidity:10%-95%, Atmospheric pressure: 40~120Kpa.  Alarm:  Air in Line /Exceed Accum. Bubbles/ Downstream Occlusion /[Pls Install the IV set correctly