Dust filter housing CANISTER
laboratoryfor healthcare facilities

Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities
Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities
Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities - image - 2
Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities - image - 3
Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities - image - 4
Dust filter housing - CANISTER - SagiCofim - laboratory / for healthcare facilities - image - 5
Add to favorites
Compare this product
 

Characteristics

Fluid
dust
Applications
laboratory, for healthcare facilities
Weight

16 kg, 21 kg, 54 kg, 85 kg, 100 kg
(35.27 lb, 46.3 lb, 119.05 lb, 187.39 lb, 220.46 lb)

Description

CANISTER safety system are duct containment systems for the safe replacement of high efficiency, HEPA, ULPA or activated carbon filters and they are designed to filter exhaust air from environments containing toxic or harmful contaminants. These systems are mainly used in industrial, laboratory and process applications and are installed directly in the hazardous environment. In the Bag-In/Bag-Out procedure spent filters are sealed inside the barrier bag and then sent for disposal, never coming into contact with any operator. Duct containment systems for the safe replacement of high efficiency, HEPA, ULPA or activated carbon filters. The system guarantees the highest tightness class thanks to the double-lip flanges, the sealing gaskets and the continuous welding. The mechanical resistance of the housing to air pressure is ±5kPa according to ANSI/ASME 510:2007. The tightness class of the system is Class 2 according to ISO 10648-2, under standard operating conditions. MATERIAL AND FINISH • steel structure painted with decontaminable white colour RAL 9002 paint • sealing gasket of the access door for maintenance, made in a single piece of plastic rubber • eccentric bars in galvanised steel VERSIONS • AISI 304 Stainless steel • AISI 316L Stainless steel • ATEX II 2 GD T6 with dissipative graphite RAL 7021 paint • ATEX II 2 GD T6 in stainless steel • Reinforced for air tightness at high pressures, up to 600kPa • Eccentric bars in stainless steel ACCESSORIES • Probes for overall leak test • Probes for scanning leak tests • Pressure drop reading panel with shut-off valves and pressure gauges: – DW1 for single fi ltration stage – DW2 or double fi ltration stage

Catalogs

CANISTER
CANISTER
4 Pages
INER-ST
INER-ST
8 Pages
DIF O.T.
DIF O.T.
8 Pages
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.