video corpo
  • Products
  • Catalogs
  • News & Trends
  • Exhibitions

Emergency ventilator DAV80
clinicalanesthesiaelectronic

Emergency ventilator - DAV80 - Shandong Dolphinmed Technology - clinical / anesthesia / electronic
Emergency ventilator - DAV80 - Shandong Dolphinmed Technology - clinical / anesthesia / electronic
Emergency ventilator - DAV80 - Shandong Dolphinmed Technology - clinical / anesthesia / electronic - image - 2
Emergency ventilator - DAV80 - Shandong Dolphinmed Technology - clinical / anesthesia / electronic - image - 3
Emergency ventilator - DAV80 - Shandong Dolphinmed Technology - clinical / anesthesia / electronic - image - 4
Add to favorites
Compare this product
 

Characteristics

Applications
emergency, clinical, anesthesia
Type
electronic
Ventilation mode
multi-mode
Configuration
benchtop
Other characteristics
with touch screen
Tidal volume

20 ml, 1,500 ml
(0.7 US fl oz, 50.7 US fl oz)

Description

●Suitable for a range of anesthesia at adult,pediatric ●Comprehensive Safety&Alarm system,make sure the operation accuracy and stability ●8 inch TFT display with touch screen,shuttle knob design, quick and efficient operation ●Powerful ventilation mode meet all complex clinical requirement ●Three levels alarm system, visual and sound alarm information. ●The core components are imported from top international and original, and the industrial control chip is chosen ●High precious sensor and valve technology make sure the pressure ,flow and volume monitor and control at high safety, stability and precision ●Built-in backup battery provide the emergency power supply to the unit. Specifications Driving gas:O2 or Air,Inlet pressure,280-600 kPa.Max flow ≤ 120 L / min. Mode:VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT. Optional: SIMV-PRVC, PRVC Waveform:Pressure,Flow-rate,Volume Loop:PV loop, PF loop,FV loop Safety Pressure:Does not exceed 6 KPa. Battery Type:Li-ion,work time more than 2 hours Parameter Setting Range: Respiratory rate::1~100 bpm; Inspiratory time:0.1 ~ 10.0 s; Respiratory ratio: 9.9:1 to 1:9.9; Percentage of inspiratory pause:0 to 50%; PEEP:OFF, 3 ~ 20 cmH2O Pressure Support:0 ~ 60 cmH2O Pressure Control:5 ~ 60 cmH2O Flow trigger: 0.5 ~ 20L/min Pressure Trigger: -1 ~ -20 cmH2O PSV Insp Termination Level:25% Monitoring Parameter Inspiratory tidal volume,Expiratory tidal volume,Minute ventilation,Spontaneous minute ventilation,Respiratory rate,Spontaneous breathing frequency,Respiratory ratio,Peak airway pressure,Mean airway pressure,PEEP,Inspiratory plateau pressure,FiO2(optional)
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.