1. Laboratory
  2. Physico-chemical analysis
  3. Oxygen sensor
  4. Shenzhen Amydi-med Electronics Tech

Oxygen sensor City MOX-4
medical

Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical - image - 2
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical - image - 3
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical - image - 4
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical - image - 5
Oxygen sensor - City MOX-4  - Shenzhen Amydi-med Electronics Tech - medical - image - 6
Add to favorites
Compare this product
 

Characteristics

Evaluation type
oxygen
Applications
medical
Pressure range

Min.: 0 mbar
(0 psi)

Max.: 1,500 mbar
(21.76 psi)

Description

MOX4 MediceL® Sensor MOX4 Oxygen Sensor Part Number: AA829-M20 KEY FEATURES & BENEFITS: 1) Meets the requirements of ISO 80601-2-55 2) Linear output from 0 % to 100 % O2 3) Teledyne T-7 alternative 4) 13-month warranty 5) RoHS compliant TECHNICAL SPECIFICATIONS MEASUREMENT Operating Principle: Partial pressure electrochemical Output: 9 mV to 13 mV, in 210 mBar O2 Measurement Range: 0 mBar to 1500 mBar O2 Response Time (T90):<15 s (air to 100% O2) Baseline Offset: <200 μV Linearity: Linear 0% to 100% O2(See Note1) ELECTRICAL Temperature Compensation: Partial compensation for Teledyne T-7 equivalence External Load Resistor:10 kΩ min. (See Important Note) Connector:UK Data Socket AMP(P/N 520257-2) MECHANICAL Housing Material: White ABS Weight: 42 g (nominal) Orientation: Any ENVIRONMENTAL Typical Applications: Critical care anesthesia Operating Temperature Range: -20°C to +50°C Operating Pressure Range: 0.5 Bar to 2.0 Bar Operating Humidity Range: 0% to 99% RH non-condensing LIFETIME Long-Term Ouput Drift in 100% O2:< 5% signal loss/year Recommended Storage Temperature:-10°C to 40°C (short excursions to 50°C allowed) Expected Operating Life: @ 20°C, 1.5 x 106 % O2 hours @ 40°C, 0.8 x 106 % O2 hours Packaging: Sealed blister Standard Warranty: 13 months from date of despatch (This amounts to a variation of condition 6 of our standard terms and conditions which otherwise apply) Note 1: The regression coefficient of the best fit line should be better than 0.9995 when measured through four data points from testing with 100% N2, 21% O2, 60% O2 and 100% O2.