Fingertip SpO2 sensor AMD-RS-PC6502-S
pediatrictransflectancereflectance

Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance
Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance
Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance - image - 2
Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance - image - 3
Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance - image - 4
Fingertip SpO2 sensor - AMD-RS-PC6502-S - Shenzhen Amydi-med Electronics Tech - pediatric / transflectance / reflectance - image - 5
Add to favorites
Compare this product
 

Characteristics

Area of the body
fingertip
Patient type
pediatric
Technique
transflectance, reflectance
Other characteristics
reusable
Material
latex-free
Cable length

Max.: 3 m
(9'10" )

Min.: 1 m
(3'03" )

Description

Compatible Nellcor OxiMax 1 Meter 9Pin Pediatric Finger Clip Reusable SpO2 Sensor Compatible Model: N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM10N, Sensors that have Nellcor OxiMax Technology and 9 pins. Cable Color:Gray Cable Diameter:4 mm Cable Material:TPU Jacket Category:SpO2 Certifications:CE, ISO 13485 Connector Distal:Male 9-Pin D-Sub Purple Connector, Dual Keyed Connector Proximal: Pediatric Finger Clip Latex-free:Yes Packaging Type:PE Bag Packaging Unit:1pcs SpO2 Technology: Nellcor Sterile:No Total Cable Length: 1 meter / 3.28ft Warranty: 12 months Weight:0.3lb Product Feature: 1) LED 660nm / 905nm, the max output power: 2 mw. 2)SpO2 test range:70%~100%;Accuracy:70%~79% /±3%,80%~89% / ±2%,90%~100% / ±1%. 3)Pulse rate test range:30~245 bpm;Accuracy:150 bpm -245 bpm /±3 bpm,60 bpm -149 bpm/±2 bpm,bpm -59 bpm/±1 bpm. 4) Under the environment temperature of 35℃. The maximum allowable temperature of the contact part between a blood oxygen probe and human body shall be no larger than 41℃. 5)Test method for measuring range and measuring precision of SpO2 :Use a supporting device matching the tested spo2 sensor;,connect the tested spo2 sensor and the supporting device, and connect them with a blood oxygen simulation tester.

VIDEO

Catalogs

No catalogs are available for this product.

See all of Shenzhen Amydi-med Electronics Tech‘s catalogs

Other Shenzhen Amydi-med Electronics Tech products

Reusable SpO2 Sensor

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.