Gas chromatography system HS-20 NX
for quality controlvolatile organic compoundfor research

Gas chromatography system - HS-20 NX  - Shimadzu - for quality control / volatile organic compound / for research
Gas chromatography system - HS-20 NX  - Shimadzu - for quality control / volatile organic compound / for research
Gas chromatography system - HS-20 NX  - Shimadzu - for quality control / volatile organic compound / for research - image - 2
Add to favorites
Compare this product
 

Characteristics

Type
gas
Applications
for research, volatile organic compound, for quality control

Description

The HS-20, developed as the best solution for volatile component analysis, has been improved and introduced as the NX series. The excellent basic performance and user-friendly design provide a powerful solution for scientists in both research and quality control laboratories. Features Next Level Performance Ultra-low carryover The HS-20 NX series uses the isolation gas flow to reduce carryover to 1/10 of conventional models. It supports a wide range of chemical species, including high-boiling point compounds and high-polar compounds, and provides reliable analytical results. The Isolation Gas Flow The isolation gas flow prevents sample diffusion from the vent channel, which has been a problem with conventional headspace samplers. (patent pending) Carryover of highly adsorptive compounds is reduced, eliminating the need for repeating blank runs Superior Usability ClickTek™ NX Connector ClickTek, adopted by Nexis™ GC-2030, has been optimized and applied to the HS-20 NX. ClickTek NX enables anyone to connect columns easily and without tools, simplifying column replacement and routine system maintenance Beyond Expectation With the trap mode of the HS-20 trap model, which can concentrate samples, 10 - 100 times more sensitive analysis can be achieved than with the loop mode. The HS-20 trap model also operates in the loop mode, giving users the flexibility to meet multiple analytical requirements. Vial capacity/Sample tray - 90-vial capacity Number of vials simultaneously heated - 12-vial capacity Sampling mode - Loop/Trap mode Max. oven temperature - 300℃ Max. sample line temperature - 300℃ Max. transfer line temperature - 350℃
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.