Medical autoclave YXQG0 series
portableautomaticstainless steel

medical autoclave
medical autoclave
medical autoclave
medical autoclave
Add to favorites
Compare this product
 

Characteristics

Applications
medical
Configuration
portable
Function
automatic
Sterilization chamber material
stainless steel
Capacity

18 l, 24 l, 29 l
(4.76 gal, 6.34 gal, 7.66 gal)

Temperature range

126 °C
(258.8 °F)

Width

325 mm, 350 mm
(13 in, 14 in)

Height

410 mm, 510 mm, 620 mm, 715 mm
(16.1 in, 20.1 in, 24.4 in, 28.1 in)

Description

YXQG Series stainless steel Portable Autoclave is a kind of sterilization equipment with pressure steam as medium. It is used for sterilizingsurgical instruments, beddings and glassware of medical units. Features Adopt microcomputer control, touch key. Dynamic display of sterilization process, LED digital display of chamber temperature, time and fault code alarm. Manual water filling and drainage, automatic control of temperature heating, sterilization and steam venting. The default parameters can be set and modified by users, the counts of positive pressure pulses, sterilization temperature, sterilization time, boiling point temperature and other parameters can be set by users. Temperature sensor control, precise control of sterilization chamber temperature. Automatic over-temperature protection device, door safety interlock device, safety valve for automatic pressure relief, short-circuit protection, over-pressure protection. Safety Protection Device Anti-dry burning device: when the water level is lower than the specified level, it can automatically cut off the heating power. Automatic steam venting device: when the pressure exceeds the set value, the steam release valve will automatically open and discharge steam to keep the sterilization pressure in the chamber. Over-pressure protection device: automatic pressure relief safety valve will open automatically to release pressure when the pressure exceeds the safety value. Door safety interlock device: If the door is not closed, the chamber cannot be pressurized, and if there is pressure in the chamber,the door cannot be opened. Electronic circuit safety device: AC main circuit with fuse.

Catalogs

No catalogs are available for this product.

See all of Shinva Medical Instrument‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

MEDICA 2024
MEDICA 2024

11-14 Nov 2024 Düsseldorf (Germany) Hall 10 - Stand D60

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.