Intraoral X-ray system X-70 DC
wall-mounteddigital70 kV

Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV
Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV
Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV - image - 2
Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV - image - 3
Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV - image - 4
Intraoral X-ray system - X-70 DC - Simple&Smart - wall-mounted / digital / 70 kV - image - 5
Add to favorites
Compare this product
 

Characteristics

Type of system
intraoral X-ray system
Ergonomics
wall-mounted
Technology
digital
Tube voltage (kV)
70 kV, 60 kV
Focal spot size (mm)
0.4 mm

Description

X-70 DC means amazing results with all the advantages of the more advanced electronic technology: rather than using alternatingcurrent, X-70 DC applies a nearly constant potential to the tube. This constant potential supplies the tube with DC current, resulting in a constant stream of consistent radiation that maintains the preset kV values even with mains fluctuations. X-70 DC with a high technological development allows getting HD images using normal films or digital images receptors (intraoral sensor and phosphor plates). The unit is available in two versions, wall mounted (with extension arm of 60 or 80 cm lenght) and mobile. Characteristics _ X-70 DC versatile advanced technology Automatic Voltage Transformer, X-70 DC appropriately works in a range from 100 to 240 V. DC Generator allows radiation stability eliminating rays that does not produce images but can be harmful for the patient. 0.4 mm Focal Spot. Tube Voltage Selector. RiX-70 DC operates either 60, 65 or 70 kV. Automatic setting of exposure time from 001 to 2.0 s. Optional remote timer (only for wall mount version). Remote control with 3 meters spiral telephone cable. Micro-process controller function. Exposure parameters automatic selection. Manually selection of exposure parameters according to the patient morphology, tooth type andimage receptor. Adapt the radiation dose to lower or higher values. Modify the exposure time for digital or film. Anatomic digital selection between Child (small) and Adult (big). Use of three different image receptors: traditional film, intraoral sensor or phosphor plates. Low dose setting using digital sensor.

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

AEEDC 2025
AEEDC 2025

4-06 Feb 2025 Dubai (United Arab Emirates) Hall 1.2 - Stand S1A21

  • More information
    IDS 2025
    IDS 2025

    25-29 Mar 2025 Cologne (Germany) Hall 3.2 - Stand A010

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.