video corpo

Rapid infectious disease test
virusSARS-COV-2saliva

Rapid infectious disease test - Spartacus-biomed - virus / SARS-COV-2 / saliva
Rapid infectious disease test - Spartacus-biomed - virus / SARS-COV-2 / saliva
Rapid infectious disease test - Spartacus-biomed - virus / SARS-COV-2 / saliva - image - 2
Add to favorites
Compare this product
 

Characteristics

Applications
for infectious diseases
Micro-organism
virus, SARS-COV-2
Sample type
saliva
Format
cassette, strip
Result display time

10 min

Specificity

99.6 %

Sensitivity

92.9 %

Description

SARS-CoV-2 Saliva Rapid Test from Spartacus-Biomed is for a rapid detection of the virus as a diagnostic aid. This device is based on the rapid immunochromatography technique for the détection of the virus in saliva samples.The test device is composed of a sample pad, a reagent pad and a reaction membrane. The assembled strip is fixed inside a plastic cassette. The reagent pad conta ins the colloidal-gold conjugated with the monoclonal antibodies against SARS-CoV-2. The reaction membrane co门tains the secondary antibodies for Sars-CoV-2 and the polyclonal antibodies against the mouse globulin, which are pre-immobilized on the membrane. When the sample is added into the sample well, conjugates (previously dried on the reagent pad) are dissolved and migrate along with the sample. I SARS- CoV-2 is présent in the sample, a complex formed between the anti-SARS- CoV-2 conjugate and the virus will be caught by the specifie anti-SARS-CoV-2 monoclonal coated on the T region. Material provided: Cassettes in indMdual packages ; Saliva colle ctor cups ; Disposable drop ping bottles with buffer ; Extraction Tubes ; Nozzles for the extraction tubes ; Tube stand ; pipettes ; User manual. Material not provided: Timer. Please read the following steps of the procédure carefuily before testing. Use freshly collected samples for optimal test performance. Inadequate sample collection or improper sample handling may yield a false-negative result Cross Reaction: The test results are belowthe corresponding concentration ofthe substances in the table below, which has no influence on the négative and positive test results of this reagent, and there is no cross-reaction.

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall Z2 - Stand C51

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.