Medical autoclave ADELA 2KK 250
laboratoryCSSDfloor-standing

Medical autoclave - ADELA 2KK 250 - Sumer - laboratory / CSSD / floor-standing
Medical autoclave - ADELA 2KK 250 - Sumer - laboratory / CSSD / floor-standing
Medical autoclave - ADELA 2KK 250 - Sumer - laboratory / CSSD / floor-standing - image - 2
Medical autoclave - ADELA 2KK 250 - Sumer - laboratory / CSSD / floor-standing - image - 3
Medical autoclave - ADELA 2KK 250 - Sumer - laboratory / CSSD / floor-standing - image - 4
Add to favorites
Compare this product
 

Characteristics

Applications
medical, laboratory, CSSD
Configuration
floor-standing, front-loading, mobile, pass-through
Function
automatic, programmable, microprocessor-controlled, with vacuum cycle, high-capacity
Sterilization chamber material
stainless steel
Options
with steam generator, with touchscreen, with dryer, with sliding door, with cooling system, with deionizer
Capacity

250 l
(66.04 gal)

Temperature range

121 °C, 125 °C, 134 °C
(249.8 °F, 257 °F, 273.2 °F)

Sterilization cycle time

20 min, 45 min, 60 min, 80 min, 90 min

Width

995 mm
(39 in)

Height

1,765 mm
(69.5 in)

Depth

1,325 mm
(52 in)

Description

ADELA-OT series steam sterilizers are designed and manufactured regarding the manufacturing and product standards. General Characteristics   Control System: PLC CPU, Dual CPU (Optional) Operation Mod: Fully Automatic / Button Command Screen Type: Multi-Color TFT, LCD Touch Screen Screen Size: 7,0" (10,0" Optional) Keypad: Touch Screen Printer: 40 Character /Line, Thermal Printer Remote Control and Communication: RS 232 Port / USB , Ethernet (Optional) Warning Sytem: Visual & Audio & Printed Data Storage: Up to 200 Cycles, 1000 Cycles (Opitonal) Monitoring Touch Screen, Anaolgue Gauges for Chamber, Jacket, Generator and Air Pressure (Manometer) Mobility 4 Easy positioning on 4 swivel castors and firm fixing on legs Steam Generator with pneumatic valves Safety and Quality Protects operator from electrical current leaks. Short circuit protection. Safety valve. Hepa filter for air filtration. Water level control via buoy in generator. Pneumatic Valves for precise exhausting. Leak test. Pre-vacuum cycle Password protection. Sensors against obstructions on the doors pathway. Doors locks under pressure. Emergency stop button. Unable to open both doors at once double door models. Relevant Directives and Standards   Medical Device Directive MDD 93/42/EEC / 2007/47/EC Medical Device Class Class IIb, MDD 93/42/EEC, 2007/47/ EC (Annex IX) Low Voltage Directive 2014/35/EU - EN 61010-2-040 - EN 61010-1 - EN 60601-1 EMC Directive 2014/30/EU EN 60601-1-2 - EN 61326-1 Pressure Equipments Directive PED 2014/68/EU : EN 13445-1, -2, -3, -4, -5 Steam Sterilizer Directive EN285 Quality Mangement System ISO 9001

VIDEO

Catalogs

No catalogs are available for this product.

See all of Sumer‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

FIME 2025

11-13 Jun 2025 Miami (United States)

  • More information
    Medica 2025
    Medica 2025

    17-20 Nov 2025 Dusseldorf (Germany)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.