Radiography test phantom KE-A03
for CT scanfor MRIknee

Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 2
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 3
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 4
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 5
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 6
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 7
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 8
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 9
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 10
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 11
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 12
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 13
Radiography test phantom - KE-A03 - True Phantom Solutions - for CT scan / for MRI / knee - image - 14
Add to favorites
Compare this product
 

Characteristics

Type of calibration
for radiography, for CT scan, for MRI
Area of the body
knee

Description

The phantom’s structure and geometry is based on an average adult human knee. The synthetic bones used in this phantom are made out of our patented bone material and the soft tissues are cast individually from our urethane-based tissue mimicking materials which are best suited for X-Ray/CT and MRI imaging applications. The phantom can be used as a tool to conduct medical imaging research, radiology training, testing, and calibration-related work. This product can be further customized to match any project’s specific requirements. In terms of MRI applications, the phantom tissues have realistic T2 relaxation time values which makes this product to be best fit for any T2-weighted MRI imaging methods. Very good results can be also achieved with Proton Density imaging methods. The phantom can be still imaged with T1-weighted methods but the T1 values are less realistic and they are within the range of about 100 ms. Upon request, this product can be customized with different pathologies as well as for specific training applications. Anatomy: • Partial Upper Leg • Partial Lower Leg • Patella • Meniscus: – Lateral Meniscus – Medial Meniscus • Condyle: – Lateral Condyle Femoral – Medial Condyle Femoral • Ligaments and Tendons: – Quadriceps Femoris Tendon – Patellar Ligament – Lateral Patellar Retinaculum – Medial Patellar Retinaculum – Anterior Cruciate Ligament – Posterior Cruciate Ligament – Arcuate Popliteal Ligament – Oblique popliteal Ligament • Bursa: – Subtendinous Bursa (3) – Semimembranosus Bursa – Pes anserine Bursa – Infrapatellar Bursa – Prepatellar Bursa – Iliotibial Band Bursa