Laboratory autoclave - ML - Tuttnauer - benchtop / semi-automatic / stainless steel
Laboratory autoclave - ML - Tuttnauer - benchtop / semi-automatic / stainless steel
Laboratory autoclave - ML - Tuttnauer - benchtop / semi-automatic / stainless steel - image - 2
Laboratory autoclave - ML - Tuttnauer - benchtop / semi-automatic / stainless steel - image - 3
Add to favorites
Compare this product
 

Characteristics

Applications
laboratory
Configuration
benchtop
Function
semi-automatic
Sterilization chamber material
stainless steel
Capacity

23 l, 85 l
(6.08 gal, 22.45 gal)

Sterilization cycle time

999 min

Width

510 mm, 660 mm
(20 in, 26 in)

Height

365 mm, 525 mm
(14.4 in, 20.7 in)

Depth

545 mm, 875 mm
(21 in, 34 in)

Description

-Sterilizes low sensitivity loads, including liquids, solids and glassware -Autoclave door is designed with a number of safety features -Chamber constructed of 316L grade stainless steel -Maintenance access to all components for easy servicing -Complies with the strictest international directives and standards Manual Laboratory Sterilizers Tuttnauer's ML laboratory line of semi-automatic, electro-mechanically controlled, vertical steam sterilizers provide safe, economical and effective sterilization. The semi-automatic laboratory autoclave series is an affordable sterilizer for laboratories that do not want to compromise on quality, safety and reliability and need to sterilize loads with low sensitivity. The ML semi-automatic series is available as benchtop autoclaves with 23 or 85 liter chambers. Process control is preformed by a pressure switch.The ML models have a semi-automatic control panel. Sterilization Applications -Liquids such as nutrient media and buffer solutions -Solid items such as pipettes, tubes and filters -Glassware and plastic articles -The chamber is constructed of long lasting 316Ti grade stainless steel with superior corrosion resistance Quality Features -A safety device prevents the operator from opening the door when the chamber is pressurized -A cycle cannot start if the door is open or not properly locked -The door cannot unlock until chamber pressure reaches room pressure -Safety Valves: The chamber is equipped with safety valves – if the pressure exceeds the allowed limit the safety valves will discharge

Exhibitions

Meet this supplier at the following exhibition(s):

ArabHealth 2025
ArabHealth 2025

27-30 Jan 2025 Dubai (United Arab Emirates) Hall H4 - Stand D11

  • More information
    AEEDC 2025
    AEEDC 2025

    4-06 Feb 2025 Dubai (United Arab Emirates) Stand 8A13

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.