Laboratory autoclave ELV - D Line
verticalstainless steel

laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
laboratory autoclave
Add to favorites
Compare this product
 

Characteristics

Applications
laboratory
Configuration
vertical
Sterilization chamber material
stainless steel
Capacity

Min.: 31 l
(8.19 gal)

Max.: 160 l
(42.27 gal)

Temperature range

121 °C, 134 °C
(249.8 °F, 273.2 °F)

Sterilization cycle time

999 min

Width

540 mm, 730 mm, 870 mm
(21 in, 29 in, 34 in)

Height

980 mm, 1,000 mm, 1,090 mm
(38.6 in, 39.4 in, 42.9 in)

Depth

440 mm, 540 mm, 770 mm
(17 in, 21 in, 30 in)

Description

-Biohazard and Waste sterilization -Agar preparation -Specialized customized cycles -Liquid sterilization with various cooling options -Pipette and Glass sterilization -Instrument sterilization (wrapped or unwrapped) ELV models have an advanced microprocessor control panel and chamber made of 316L or 316Ti stainless steel.Tuttnauer laboratory autoclaves have been designed to provide high quality repeatable performance and accountability for a wide range of applications used in modern laboratories. Each model has a number of optional added-value features which can be configured for fast cooling, efficient drying, biohazard and waste sterilization, Fo control, and more. Vertical lab autoclaves are designed for your convenience and ease of use when vertically loading the autoclave. Vertical stainless steel wire baskets and containers in different sizes for all autoclave models. Safety Safety for personnel, autoclave and load are priority in the design, construction and operation of any Tuttnauer autoclave. Tuttnauer is committed to the highest industry safety standards and directives to ensure safety not only for your employees operating the autoclaves but also for your laboratory and the loads being sterilized. -A safety device prevents the operator from opening the door when the chamber is pressurized -Steam will not enter the chamber when the door is open -A cycle cannot start if the door is open or not properly locked -The door cannot unlock until liquid temperature reaches the predetermined end temperature Two independent flexible PT100 temperature sensors to prevent over-boiling of liquids and explosions of bottles

Catalogs

No catalogs are available for this product.

See all of Tuttnauer‘s catalogs

Exhibitions

Meet this supplier at the following exhibition(s):

Analytica China 2024
Analytica China 2024

18-20 Nov 2024 Shanghai (China)

  • More information
    ArabHealth 2025
    ArabHealth 2025

    27-30 Jan 2025 Dubai (United Arab Emirates) Stand H4.D11

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.