supply voltage: 230 V 50 Hz
element emits UV-C radiation: 1x15 W
radiation UV- C intensity at the distance
useful lifetime of the bulbs: 9000 h
effective area of the lamp: 6-8 m2
exposure angle adjustment range: 240 °
anti-shock protection class: I
ingress protection code: IP 20
operation mode: continous
height of the stand: 1800 mm
A detailed description of the ways and methods of UV-C germicidal lamps use is contained in the user's manual provided with the product.
Selection of the power and number of NBV series direct radiation- direct action UV-C germicidal lamps depends on many factors, such as:
ceiling height
shape of the room
reflectance of surfaces (walls) in the room
temperature
humidity
degree of dust pollution in the air
resistance of microbes
The multiplicity of parameters, which should be taken into account in selection of the lamps make it impossible to formulate a clear, simple way for determining precisely the recommended quantity of NBV series direct radiation germicidal lamps in particular room.
*in the interior height of 2.5m to 3.0m in the room conditions.
Depending on the purpose of the room (patient room, doctor’s cabinet, treatment room, operating room) lamps are turned on for 2 to 8 hours. In order to obtain the temporary effect of air disinfection in the room (e.g. between two treatments) the lamp should be turned on for 15 to 20 minutes.