Laboratory vacuum pump PC 611 select
electronicdiaphragm

Laboratory vacuum pump - PC 611 select - Vacuubrand - electronic / diaphragm
Laboratory vacuum pump - PC 611 select - Vacuubrand - electronic / diaphragm
Add to favorites
Compare this product

Characteristics

Applications
laboratory
Technology
electronic, diaphragm
Flow

Min.: 0 m³/h
(0 ft³/h)

Max.: 3.4 m³/h
(120.07 ft³/h)

Power

0.25 kW
(0.34 hp)

Pressure

1.5 mbar
(0.02 psi)

Inlet fitting size

Min.: 8 mm
(0.3 in)

Max.: 10 mm
(0.4 in)

Outlet fitting size

Min.: 8 mm
(0.3 in)

Max.: 10 mm
(0.4 in)

Weight

20.6 kg
(45.4 lb)

Length

435 mm
(17.1 in)

Width

243 mm
(9.6 in)

Height

457 mm
(18 in)

Description

VACUU·SELECT vacuum controller with graphical user interface simplifies work in the laboratory predefined applications save time and give reproducible results easy-to-use application editor allows own process sequences meets high vacuum requirements for most high boiling solvents PC 611 select allows simultaneous operation of two independent vacuum applications This chemistry vacuum pumping unit is an economic space-saving solution for simultaneous operation of two independent vacuum applications with one single pump. Based on our popular MD 4C NT three-stage chemistry diaphragm pump, the PC 611 select is frequently used for vacuum applications involving even high boiling point solvents. This pump has sufficient capacity for parallel operation of two demanding applications. One application is controlled by the VACUUSELECT vacuum controller an electronic solenoid valve. The second application is controlled by a manually controlled diaphragm valve. Both vacuum ports have integrated check valves to protect against cross contamination and interference. The integrated VACUU·SELECT controller provides an easy-to-use, application based interface that covers all common lab applications. The VACUU·SELECT controller has you covered. Use manual set-point-control for simple processes, run distillations, or create your own application with simple drag-and-drop editing. For solvent evaporation, it detects the boiling pressure and switches to 2 point control mode to hold the pressure stable when a boiling point is detected.

VIDEO

Exhibitions

Meet this supplier at the following exhibition(s):

Forum Labo 2025

25-27 Mar 2025 Paris (France)

  • More information
    *Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.