Isolation module with forced ventilation system. On the side of the module there is a bar for hanging infusomats.
Description of the first floor:
Two cages isolated from each other.
No inner trays, no perforated floor.
Cages have two closed sockets for connecting heating mats with a size of 400x500mm.
Cage doors made of plastic with one glass pane with vertical bars and gaskets for tight and airtight closing.
Lighting in each cage.
Cages are equipped with fittings for oxygen connection, and special holes for carbon dioxide outlet.
Overall dimensions of each cage: 700x800x800h.
First floor dimensions: 1400x800x800h.
Description of the second floor:
Two isolated between each other cells.
In each cage closed sockets to connect the mats with heating 400h500mm.
The presence of trays-no, the presence of perforated floor-no.
Single-glass plastic doors with seals for tight closing.
Lighting in each cage.
Cells equipped with nozzles for oxygen, and special holes for carbon dioxide outlet.
Overall dimensions of each cage are 700x800x600h.
The third floor is similar to the second.
Description of ventilation system: each cell has an air inlet and air intake, which are combined in the ventilation system behind the back wall of the module, with the possibility of connecting to the ventilation shaft.
Ventilation principle: the air exhaust from the boxes is forced by a duct fan. The inflow of fresh air is carried out by changing the atmospheric pressure in the boxes provided by the fan. Shifters, installed in the ventilation holes in the boxes, allow regulating the inlet and outlet ventilation independently in each cell.
The switch for ventilation is located on the right side.