The veterinary electrosurgical unit is used for surgical dissection and coagulation of biological tissues and vessels during surgical operations.
The electrosurgical unit is the universal solution for monopolar cutting, coagulation and bipolar coagulation.
The unique mode of the patented bipolar SPRAY coagulation technology is a non-contact method of stopping surface capillary bleedings with the help of plasma.
Unique advantages:
Monopolar cutting/coagulation.
Bipolar coagulation.
Non-contact coagulation.
Enhanced coagulation/pulse mode.
Main data:
Network:220 V, 50 Hz
Power consumption from the mains:no more 150 VA
Sound level when switching on the modes:not less 65 dBA on the frequency (1000 ± 50) Hz
Ambient operating temperature range:from +10°C to +35°C
Permissible relative humidity:45-80%, non-condensing
Dimensions of the main unit:225х227х86 mm
The weight of the main electrical coagulator unit:no more 5 kg
Nominal basic frequency: 440±20 kHz
Rated output power: Monopolar cutting/coagulation 100 W, Bipolar soft coagulation of the second exit - 80 W, Bipolar enhanced coagulation of the second output - 40 W.
Nominal load: Monopolar cutting/coagulation - 200 Om, Bipolar soft coagulation of the second exit and Bipolar enhanced coagulation of the second output - 100 Om.
Peak voltage, no more: Monopolar cutting/coagulation - 190 V, Bipolar soft coagulation of the second exit and Bipolar enhanced coagulation of the second output - 150 V.
Basic equipment includes:
Electrosurgical unit.
Monopolar electrode holder + knife electrode.
Rod Electrode Ø 1 mm.
Ball Electrod Ø 3 mm.
Neutral electrode (plate-small size 180x120 mm).
Bipolar steel tweezers.
Foot pedal.